C
PROGRAMMABLE FUNCTION SETTINGS
LED
Definition
Display
Options of
Gate
1
Opening
direction
Automatic
2
Closing
There actions of
the photocells
/ safety edge /
3
loop detector
when they
detecting
obstacles
4
Motor Speed
(% full speed)
The
deceleration
5
setting
for gate moving
Deceleration
6
Speed
(% full speed)
Function
Clockwise
1-1
Opening
Counterclckwise
1-2
Opening
2-0
No automatic closing
2-1
5 seconds
2-2
15 seconds
2-3
30 seconds
2-4
45 seconds
2-5
60 seconds
2-6
80 seconds
2-7
120 seconds
2-8
180 seconds
3-1
Please the
3-2
function setting
after H & J.
3-3
4-1
4-2
4-3
4-4
5-1
75% of full distance
5-2
5-3
5-4
5-5
6-1
6-2
6-3
6-4
Value
1. The function can adjust
the direction of gate
opening.
2. The factory setting is
«1-1».
1. This function can
adjust the gate closing
automatic after the
paused time.
2. The factory setting is
«2-0": no automatic
closing.
1. Please do the function
setting after H & J
2. The factory setting is
"3-1".
slow
medium
fast
very fast
80%
1. The factory setting is
85%
"5-1".
90%
95%
80%
60%
1. The factory setting is
"6-4"
40%
25%
EN
Description
EN ::: 43