Basic Operation
continued
Other UPS Features
AC Receptacles: The receptacles provide your connected equipment with AC
line power during normal operation and battery power during blackouts and
brownouts. They also protect your equipment against damaging surges and line
noise.
Tel/DSL Protection Jacks (Select Models Only): These jacks protect connected
equipment against surges travelling over the modem/fax or telephone line.
Connecting your equipment to these jacks is optional. Your UPS will still work
properly without this connection.
USB or DB9 Communication Port: These ports can connect your UPS to any
computer for automatic file saves and unattended shutdown in the event of a
power failure. Use with Tripp Lite's PowerAlert Software and appropriate USB
or DB9 cable. A PowerAlert CD and USB or DB9 cable may be included with
your UPS; if so, insert the CD into the CD tray of your computer and follow the
installation instructions. If PowerAlert Software and the appropriate cable did
not come with your UPS, you can obtain the software FREE via the Web at
www.tripplite.com. Any user-supplied DB9 pass-through or USB cable may then
be used to connect your UPS to your computer.
Note: This connection is optional. The UPS will work properly without this connection.
Battery Replacement Door: Under normal conditions, the original battery in
your UPS will last several years. Battery replacement should be performed only
by qualified service personnel. Refer to "Battery Warnings" in the Safety section.
Should your UPS require battery replacement, visit Tripp Lite on the Web at
www.tripplite.com/products/battery-finder to locate the specific replacement
battery for your UPS.
External Battery Connector (Select Models Only): Use to connect one or
more Tripp Lite battery packs for additional runtime. Refer to Specifications and/
or the label next to the connector to determine the appropriate variety of battery
pack to use. Refer to the battery pack instruction manual for complete installation
information and important safety warnings.
Input Breakers: Protects your electrical circuit from overcurrent draw from the
UPS load. If breaker trips, remove some of the load, then reset it by pressing the
breaker in.
Equipotential Connection: Use this to connect any equipment that requires a
chassis ground.