OPERATION
Control Panel:
Burner Knobs
Top Burners:
1. Connect the gas supply and ignite the pilot flame with a lighter. If the device is stopped using for a
long time or first used, it is normal that the duration of ignition may be a little longer (about two or three
minutes).
2. Turn the corresponding valve knob of burner counter clockwise, the burner will be ignited. If the
knob is aligned with the round dot on the panel, the flame is Max. To set the flame to Min, rotate
counterclockwise to the Min flame position.
3. After using, turn off the main burner. To shut down, rotate the knob clockwise to origin position.
4. If not using the device, please turn off all the burner valves.
Off Position
High Position
Operating the Griddle – Pilot Lighting Instructions for MANUALLYCONTROLLED GRIDDLES
Before operating Griddle, it should be checked to see that is sitting level. Adjust the feet to level the Griddle. Be sure the
catch tray had been properly placed.
Manual Griddle Knob
The pilot light on the appliance has been set at the factory. Each burner has a pilot light.
1. Make sure all knobs are in the "OFF" position.
2. The main gas valve should be "CLOSED/OFF" for five (5) minutes prior to lighting plots to clear any existing gas.
(Main gas valve is supplied by others.)
3. Turn "ON or OPEN" the main gas valve to the unit.
4. Light and hold an ignition source (match) at the pilots. When the flame is established, remove the ignition source.
Repeat this step for each burner as each burner has its own individual pilot. The pilot can be reached through the
holes in the front of the unit.
5. Turn each burner knob "ON". If the burners do not ignite promptly, turn the knobs "OFF". From the opening in the
front panel, use a screwdriver and turn the pilot valve screw counterclockwise, which will increase the flame height
Range Owner's Manual Rev 20180822
Crumb Tray
9
Pilot Adjustment Valves
Low Position
For Warranty Service Call 866-909-2855