Installation Instructions - WPLLED
INSTALLATION
Applications
These luminaires are designed for outdoor, wet location
services and should not be used in areas with limited
ventilation or in high ambient temperature enclosures. The
luminaire shall be wall mount only. Inverted mounting will
cause overheating and possible water entry.
Tools Required
Philips screwdriver, Torx T-20 bit (included), 6mm multi-bit
screw driver or 6mm socket, 1/4" drill bit.
1.
Open the fixture by loosening the two tamper resistant
screws with the Torx T-20 bit (included) on the side and
remove the glass door assembly. Remove drain plugs
(Figure 1. - Figure 2.)
2.
Prepare the back plate for mounting by drilling or
knocking out the appropriate holes. (Figure 3.)
3.
Line up the back plate in the desired location and
mount securely. Caulk all holes in the back plate,
mounting and conduit holes. Caulk around backplate
where the luminaire contacts the mounting surface to
provide a watertight seal.
4.
If using electrical conduit, remove the screw cap from
the desired conduit hole and replace with conduit.
Route the branch circuit wires inside the fixture. If
using a junction box, bring the branch circuit wires
through the rear hole into the fixture.
5.
Splice the branch circuit power leads to the fixture
power leads, black to black (hot), white to white
(neutral), and green to green (ground).
6.
Reattach the LED module and driver module to the
back plate.
7 .
Replace the lens assembly using the provided
tamper-proof screws.
Mounting
The back plate has a cast-in drill and knock-out template
to match any standard recessed junction box, three 5/16"
knock-outs for mounting holes A and three 1/2" NPS tapped
holes D for surface conduit or photocontrol unit.
A – 1/2" NPS tapped holes.
●
●
B – 5/16" diameter knockouts.
●
●
To weatherproof your outdoor installation, all gaskets
N
ote:
must be seated properly and all screws inserted and
tightened firmly. Apply weatherproof silicone sealant
around all edges between the fixture housing and
mounting surface.
N
ote:
Mounting height to be a minimum of 6 feet.
2
COOPER LIGHTING SOLUTIONS
IB514014EN
Installation instructions
Figure 1.
WPLLED100
Figure 2. WPLLED125
A
Figure 3.
A
B
A