Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ELECTRICAL
 Picture 5
1. Plug the transformers output lead into the socket on the
control valves power cord; secure it by means of the
TwistLock clamp.
2. Plug the transformer into an electrical outlet.
PRESSURIZING
1. Make sure the bypass system is in 'bypass' position.
2. Make sure the electronic controller of the appliance is in
service mode.
3. Open the mains water supply.
4. Open a cold treated water faucet nearby the appliance
and let the water run for a few minutes until all air is
purged and all foreign material that may have resulted
from the installation is washed out; close the tap.
5. Gently pressurize the appliance, by putting it into service:
factory bypass:
1. open the 'outlet' valve;
2. slowly open the 'inlet' valve.
3-valve bypass:
1. close the 'bypass' valve;
2. open the 'outlet' valve;
3. slowly open the 'inlet' valve.
6. After 2-3 minutes, open a cold treated water faucet
nearby the appliance and let the water run until all air is
purged from the installation and the filter media is
properly rinsed (it is normal for the rinse water to show
some discoloration!); let the water run until the rinse
water is clear; close the faucet.
7. Check the appliance and all hydraulic connections for
leaks.
During the passage through the compressed air
chamber, the treated water will get highly oxygenated. As a
consequence it may become slightly non-transparent (milky
appearance) when it flows from the tap into a glass. This is
totally harmless for the quality of the treated water and will
disappear rapidly if the water is left standing for a moment!
ELECTRONIC CONTROL PANEL
1. Program the electronic controller.
PERFORM REGENERATION
We recommend to postpone the execution of this 'start-
up' regeneration by at least 2 hours. The filter media needs
sufficient time to absorb water and reach its normal service
weight. If the regeneration is performed too soon, the filter
media may be pushed against the top distributor during the
backwash cycle, possibly resulting in loss of filter media or
damage to the top distributor.
1. Manually initiate a regeneration, by pressing the scroll
button; the display will show:
Regen in 10 sec

COMMISSIONING

2. Leave the appliance in this position; the countdown timer
will count down to 0 sec and start a regeneration.
Page 7
EN - English

Publicité

Table des Matières
loading

Table des Matières