OPERATING INSTRUCTIONS
WHEN CHARGING NiCd BATTERY PACK K18-NB15A
ICON
c
Charging will start when battery is within temperature range: 41°F (5°C) - 104°F (40°C)
d
Battery voltage is very low; normal charging will begin in 1-2 minutes.
e
After approx. 10 minutes the charger will re-evaluate.
BACKLIGHT
FLASH RATE
Green
Steady
None
Orange
Slow flash
Flashes
Orange
slowly
Red
Rapid flash
Moves from
Orange
left to right
Green
Steady
None
DURATION
2 seconds
Indefinite
2 minutes
Indefinite
8 hours
Indefinite
15
INDICATION
Power on;
ready to charge
Power on;
no battery installed
c
Hot/cold battery
d
Deep discharge
e
Defective battery
Charging
Fully charged
Fully charged after
8 hours on charger