GREENLINE GRE 6 Mode D'emploi page 7

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

When operated, an internal electric motor powers a
hydraulic pump which supplies fluid to the cylinder of the
tool, moving the ram forward and applying force to spe-
cially designed tool heads.
The tools come with two (2) fabric loops that can be
used with appropriate attachments such as shoulder
straps or tie off lanyards.
The tools are equipped with a bright work light that turns
on when the run switch is depressed.This allows the
user to easily illuminate the work area.
The tool status lights indicate the tool's status (tool
ON/OFF, temperature out of range, service required, etc.).
See specific head instructions for specifications and other
information.
QCS Type
Label
QCS Sleeve
LED
Pressure
Work
Release
Light
Run
Button
Switch
Warning Labels
Figure 1 – GRE 6 - Use QCS Coupling for head attachment
Control
Marking
On/Off Button
Run Switch
Pressure
Release Button
QCS Sleeve
Figure 4 – Controls Chart
Green
Red
Yellow
Figure 5 – Tool Status Lights
999-999-200.10_REV A
Fabric Loop
Battery
Description
I/O
Main tool power switch (I = On, O = Off).
Depress to advance tool ram. In most cases, hold until ram automatically retracts.
Allows tool ram retracted prior to automatic retraction. Primarily used with Punch Heads.
If used with a crimp head, crimp is NOT complete and must be repeated.
Used to retract QCS balls and change heads.
Solid Light
Icon
Green
Red
Yellow
Figure 2 – Tool Status Lights
Figure 3 – Machine Serial Number - The first 4 digits (cir-
cled) indicate the year and month of manufac-
ture. (12 = year, 06 = month).
Blinking Light
Meaning
Tool ON, ready to use.
Green
Battery low. Tool will not operate. Recharge
battery/Insert fully charged battery.
Tool out of Specification temperature range. Bring tool
and battery to correct operating temperature range.
Indicates service interval approaching. Starts 2,000
Yellow
cycles prior to service interval (see Figure 7). Tool is
usable, but tool will lock after service interval.
Tool is locked. Tool has completed service interval
(see Figure 7) and requires service.
Tool has malfunctioned. Have serviced.
LED
ON/OFF
Button
5

Publicité

Table des Matières
loading

Produits Connexes pour GREENLINE GRE 6

Table des Matières