Parameter setting for MC 1500
Precise setting of the parameters only
by computer control of the MC 1500.
The MC 1500 controller's keypad only
allows rough visible adjustment.
* The values indicated with * can
only be changed via computer .
The values indicated with
derivative values that cannot be
directly set.
64 | VisiLED-Serie
Properties
Light
intensity setting
MC 1500
brightness ranges:
1 = No LED lit up
2 = One green LED 2 – 32
3 = Two green LEDs 33 – 59
4 = Two green and 60 – 82
one yellow LED
5 = Two green, one 83 – 100
yellow and one
red LED
Rotation mode
Angle of single
rotation step
illumination time
of each step *
Rotation speed*
Strobe mode
Strobe cycle
duration
Strobe frequency
Strobe pulse
duration
Strobe
intensity*
Trigger mode
Light pulse
duration
Light pulse
intensity*
Delay time*
are
Flash mode
Flash
duration
Values
%
0 – 100
0 – 1
45°
2 – 500
0.25 – 62.5 rps
μs
100 – 65000,
(full intensity from on 500 μs)
strobe frequency 15 – 2000 Hz
(10000 Hz)
μs
80 – 65000
%
0 – 100 without overdrive
0 – 300, if overdrive conditions fulfilled
(see Section 8.6)
μs
80 – 65000
0 – 100 without overdrive
0 – 300, if "pulse duration < 10000 μs"
ms
0 – 16000 (only limited settings
possible via controller keypad)
μs
80 – 65000
Tested in
accordance
with
Base setting
32 %
125 ms
1 rps
Deactivated
40000
20 Hz
2500
300
Deactivated
2500
300
1000
2500