For connection, special cables for high data flow
should be used. Standard microphone cables with
screening and a minimum cross section of 2 ×
0,22 mm
2
and with a capacity as low as possible
can only be recommended for a total cable length
of up to 100 m. For cable lengths exceeding 150 m
it is recommended to insert a DMX level matching
amplifier (e. g. SR-103DMX from "img Stage Line").
1) Connect the DMX input (11) to the DMX output
of the light controller.
2) Connect the DMX output (12) to the DMX input
of the next light effect unit. Connect its output
again to the input of the following unit, etc. until
all light effect units are connected in a chain.
3) Terminate the DMX output of the last DMX unit
of the chain with a 120 Ω resistor (> 0.3 W): Con-
nect a corresponding terminating plug (e. g.
DLT-123 from "img Stage Line") to the jack.
7.2 Adjusting the start address
For operating the unit with a light controller, adjust
the DMX start address for the first DMX channel. If
e. g. the address 5 on the controller is provided to
control the light effect unit, adjust the start address
5 on the LED-320RGBW. The DMX channels 2 and
3 are then automatically assigned to the two fol-
lowing addresses (in this example 6 and 7). As the
next possible start address for the following DMX-
controlled unit, the address 8 could be used in this
example.
Press the button MODE (6) so many times until the
display (4) shows the address last adjusted, e. g.
. Then adjust the address with the button UP
or DOWN (8).
After adjusting the start address, the light effect
unit can be operated via the DMX controller. Once
DMX signals are received, the point behind the let-
ter
in the display indication will flash.
8 Cleaning the Unit
The six lenses should be cleaned at regular inter-
vals, depending on impurities caused by dust,
smoke or other particles. Only this will ensure that
the light is radiated at maximum brightness. For
cleaning, disconnect the mains plug from the
socket. Only use a soft, clean cloth and a mild
detergent.
For cleaning the other parts of the housing, only
use a soft, clean cloth. Never use any fluid; it may
leak into the unit and cause damage.
All rights reserved by MONACOR
may be reproduced in any form or by any means for any commercial use.
9 Specifications
Power supply: . . . . . . . . . 230 V~/50 Hz
Power consumption: . . . . 30 VA
Illuminant: . . . . . . . . . . . . 156 super bright LEDs
Ambient temperature: . . . 0 – 40 °C
Dimensions, weight: . . . . 32 × 35 × 33 cm, 4.2 kg
9.1 DMX channels
Channel 1: Rotation
102 – 255 automatic rotation slow → fast
Channel 2: Pattern /chase (running light effect)
104 – 111 pattern 13
112 – 119 pattern 14
120 – 127 pattern 15
Channel 3: Stroboscope effect /chase speed
Subject to technical modifications.
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual
DMX
Function
value
0 – 100 rotation 0°→ 180°
101
no rotation
DMX
Function
value
0 – 7
LEDs off (blackout)
8 – 15
pattern 1
16 – 23
pattern 2
24 – 31
pattern 3
32 – 39
pattern 4
40 – 47
pattern 5
48 – 55
pattern 6
56 – 63
pattern 7
64 – 71
pattern 8
72 – 79
pattern 9
80 – 87
pattern 10
88 – 95
pattern 11
96 – 103 pattern 12
DMX
Function
value
(depending on the adjustment of channel 2)
if a pattern has been adjusted for channel 2
0 – 7
no stroboscope effect
stroboscope effect slow → fast
8 – 255
if a chase programme has been adjusted for channel 2:
chase speed slow → fast
0 – 255
(48 × red, 36 × green,
36 × blue, 36 × white)
DMX
Function
value
128 – 135 chase 1
136 – 143 chase 2
144 – 151 chase 3
152 – 159 chase 4
160 – 167 chase 5
168 – 175 chase 6
176 – 183 chase 7
184 – 191 chase 8
192 – 199 chase 9
200 – 207 chase 10
208 – 215 chase 11
216 – 223 chase 12
224 – 231 chase 13
232 – 239 chase 14
240 – 247 chase 15
248 – 255 chase 16
GB
9