oPERATING INSTRuCTIoNS
bEFoRE oPERATING ThE AIR PuRIFIER:
1. Carefully remove your air purifier box and bag.
2. Remove rear cover, remove filter from bag, then return filter to unit.
3. Select a firm, level and flat location for the air purifier.
* For proper air flow, locate the unit at least 1 foot from any wall or furniture.
* Make sure none of the grills are blocked.
4. Plug the power cord into a 120V AC outlet.
IMPoRTANT
:
When moving the air purifier, always lift unit by the carrying handle located on back.
oPERATING ThE AIR PuRIFIER:
1. Turn unit power ON.
2. Select fan speed MODE 1 - 5
(1 = lowest speed setting; 5 = highest speed setting)
3. Select UV-C ON or OFF using UV-C Power Button.
4. TIMER:
If you prefer to run the purifier for a specific
number of hours, you can select between
1 and 8 hours on the display.
The Air Cleaner will beep for 30 seconds and the Filter reset light will flash continuously
indicating that is is time to replace your filter. Replace the filter according to directions
then insert pen tip into Filter Reset area on control panel to restart the system. Depending
on usage, filter will last approximately 6 months.
E-8
INSTALLING & REMovING uv-C buLb
1. Remove the Rear
2. After removing
Cover of the unit
the Rear Cover
by pushing Lock &
from the unit,
Release Button.
remove the
Combination Filter.
4. The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and
pulling the bulb straight out of the unit. (Fig. 4).
bulb is NoT visible
until the uv-C METAL
ShIELD has been
removed.
FIG. 4
5. The UV-C Bulb is reinstalled by sliding it, horizontally, back into the slots at the top of the unit. .
3. After removing the
Combination Filter,
use a Philips head
screwdriver to
remove four (4)
screws and detach
the UV-C Metal
Shield.
TWIST buLb
1/4 TuRN To
REMovE.
REPLACEMENT buLb: Lb5000
AvAILAbLE AT 866.603.5900 oR
WWW.GuARDIANTEChNoLoGIES.CoM
E-9