Operating Instructions and Parts Manual
Plunger Pumps
Service Pumps (Continued)
3.
Install the valve cap and
torque to the proper
specifications. (See
figure 6)
Inlet Valves:
Disassembly:
1.
Remove the manifold.
2.
Remove low
pressure seals, insert
screwdriver under
seal lip and lift up.
(See figure 7)
3.
Using a reversible
pliers, carefully remove
the packing retainers
(plunger guides). (See
figure 8)
NOTE: You do not want
to damage these so they can be
reused if not worn.
4.
Remove the high-
pressure packing by
pulling straight out
with your finger. (See
figure 9)
5.
Pull out the valve
cage/head ring
assembly, valve
poppet, spring and
O-ring.
(See figure 10)
7
6.
7.
Assembly:
1.
Figure 6
2.
3.
Figure 7
Figure 8
4.
5.
Figure 9
6.
Figure 10
SRMV Series Pumps
Inspect for any debris or damage.
Remove the valve O-ring.
Install the valve seat
O-ring squarely into
the bottom of the
manifold.
(See figure 11)
Insert the valve
assembly and push
squarely into the
O-ring. (See figure 12)
Install the high-pressure
packing by placing it into
the cylinder at an angle and then
pushing into place.
NOTE: The point of the "V" or
flat side of the packing is pointed
at you.
Lubricate the packing retainer
O-ring with a light film of oil and
install it into the cylinder.
Push it completely into
place.(See figure 13)
NOTE: The O-ring
will seat just inside the
manifold and you will hear a
slight pop.
Insert the low
pressure seal by
placing it into the
cylinder in at an
angle and pushing it into
place. (See figure 14)