Installation Steps - Burcam 300735 Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Application
☐ This submersible sump pump is designed for
a permanent sump installation. It can be used
in light commercial application and is great for
water transfer from flodded areas.
☐ Capacity:
5'
4000 US GPH
10'
3300 US GPH
15'
2650 US GPH
20'
1580 US GPH
IMPORTANT NOTICE
The following are minimum requirements in order to protect your residence from flooding. It is a small
investment but it is your personal responsibility to protect your home, family and valuables. Failure to
comply with the following requirements may also void your warranty:
• T wo (2) pumps have to be installed in the sump pit. The first pump as a primary pump and the second
pump as the backup unit.
• Burcam alarm system model 450454 has to be installed to advise you of any malfunctions.
• A s sump pumps are electrically powered and activated so to prevent flooding, a Burcam battery
powered back up pump model 300403 has to be installed to evacuate the water.
Pump selection, proper and adequate installation are a must to comply with local by-laws and need to be
adhered to.
We recommend that you install your pump in a clean location where there is adequate
STEP 1
room for servicing at a later date. Protection from freezing temperatures and good
ventilation should be considered as well, to provide the pump an environment for
long life. Do not use to pump gas or toxic fuels. This submersible sump pump is
designed to pump water only.
Friction losses in the discharge pipe must be taken into consideration when the
horizontal offset is greater than 50 feet. The discharge pipe should be increased from
1 1/2" to 2". This will reduce friction losses and allow the pump to give maximum
performance.
More friction losses must also be taken into consideration when many elbows and
fittings are installed in the discharge line. Each elbows and fittings must be considered
as 1 feet of head.
T he float switch of your pump has been pre-set at the factory and does not need any
adjustment.
Never run the pump dry. Damage to the seal may occur. Fill pump pit or sump
basin with water before turning on the power.
A ssuming that you have a sump pit located in your basement floor... Your sump pit
STEP 2
may be constructed from concrete, brick, tile or more recently a sump basin made
from plastic and/or fiberglass. The minimum size of your sump pit should be 18" in
diameter and no less than 25" deep. When pit is ready, proceed to next step.
Friction loss in pipe
not included

INSTALLATION STEPS

Please note before you proceed with the installation of this product that the
manufacturer's guideline has to be respected. Failure to comply may void your
warranty.
Features
☐ Cast iron pump body
☐ Stainless steel motor body
☐ Stainless steel mechanical rotary seal
☐ Thermal and overload protection
☐ Oil filled motor
☐ 1/2HP, 115VAC, 60Hz, 6.3A, (12.0A when start)
3

Publicité

Table des Matières
loading