TROUBLE SHOUTING GUIDE CHECKLIST
NEVER MAKE ADJUSTEMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH
THE POWER CONNECTED. DON'T JUST UNSCREW THE FUSE OR TRIP THE BREAKER,
REMOVE THE POWER FROM THE RECEPTACLE.
TROUBLE
Motor does
not run.
Pump does not
deliver to full
capacity.
Pump does not
shut off.
6
PROBABLE CAUSE
Switch is off position
Blown fuse
Tripped breaker
Plug disconnected
Corroded plug
Low water level
Thermal overcharge
Defective switch / float
Defective motor
Improper float position
Jammed impeller
Plugged check valve
Blocked suction / inlet
Discharge leak
Blocked line / pipe
Worn impeller
Defective motor
Defective switch
Float obstruction
Blocked suction / inlet
If you have any problems with the product, before advising the store, where
you've purchased the pump, please contact us at 514 337-4415, and ask
for our sales departement, and they will be pleased to help you with any
questions you might have, concerning your installation.
ACTION
Turn switch to on position
Replace
Reset
Re-install
Clean prongs
Add water and verify
Cool the motor
Replace
Replace / repair
Check movement
Clean
Clean / replace
Check for debris in pit and clean
Repair
Check for debris or ice
Repair / replace
Replace
Replace
Adjust / check
Check for debris in pit and clean