LED INDICATORS:
POWER
Steadily lit: - Mains power on - Board powered - Fuses intact
START
Lit: START input activated
OPEN
Lit: OPEN pedestrian input activated
STOP
Unlit: STOP input activated
PHOT
Unlit: PHOT photocell input activated
FAULT 1
PHOT input safety device test input diagnostics
BAR
Unlit: BAR safety edge input activated
FAULT 2
BAR input safety device test input diagnostics
Unlit: leaf fully closed
SWC
Lit: motor limit switch is disengaged
Flashing: end of the work time while closing
Unlit: leaf fully open
SWO
Lit: motor limit switch is disengaged
Flashing: end of the work time while opening
Unlit: no error
ERR
LIT: see error diagnostics table
Unlit: remote programming not active
Slow flashing only of Radio led: Radio programming active, awai-
RADIO
ting release of the wanted button.
(GREEN)
Slow flashing only of Radio led: quitting the radio programming.
Lit: remote programming active, waiting for desired key.
Lit 1s: Radio receiver channel activated
Lit: Set key pressed / Autoset completed successfully
Flashes three times: Autoset in progress
Fast flashing 10s: Autoset failed
SET
Flashing in sync with Radio LED: Transmitter deletion in progress
Lit 1s: Start/Stop after key S3 pressed
Lit 10s: Autoset completed correctly
Terminal
L
N
GND
10
11
12
20
21
41
42
43
50
51
52
60
61
62
22 -
SHYRA AC F SL 600 PJ - SHYRA AC F SL 800 PJ
INSTALLATION MANUAL
Definition
LINE
NEUTRAL
EARTH
START + CONDENSER
COM
START + CONDENSER
AUX 0 – POWERED CONTACT
230V (N.O.) (40W MAX)
+REF SWE
SWC
SWO
0V-
24V+
24 Vsafe+
Common
START
OPEN
TABLE ERR
Unlit
Lit
slow
flashing
Single-phase power supply
with earth cable
Motor and condenser connection
Exit due to FLASHING LIGHT
Contact stays closed while leaves are operating.
Limit switch common
Closing limit switch SWC (N.C.)
Opening limit switch SWO (N.C.)
Accessories power supply output.
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output act ive only during operating cycle.
START and OPEN inputs common
START command button (N.O.).
Operation according to "Residential / apartment building operation" logic
OPEN command button (N.O.).
Gate opened with this command. If the input stays closed, the leaves stay open until the
contact is opened.
When the contact is open, the automated device closes following the TCA time, where
activated.
Led ERR
Lit
slow flashing
Photocell test,
Costa o Costa
8k2 failed
- Check photo-
cell connection
and/or logic
settings
Reverse due to
obstacle - Ampe-
rostop
- Check for obsta-
cles in path
Test hardware card
error
- Check the
connection to the
motor
- Hardware pro-
blems to the card
(contact technical
assistance)
Thermal
- Wait for the auto-
mation to cool
Description
fast flashing
Thermal cutout
- Allow automated
device to cool
Changed settings
and/or Operating
logics press S2 for
5s to confirm.