8 Troubleshooting

Please note, that if a power failure occurs because the power cord is disconnected,
or if the ON/OFF button has been pressed during an ice -making cycle, small ice chips
may form and cause the shovel to jam. If this happens, the ice chips can be removed
by disconnecting the power cord and gently pushing the shovel to the rear of the unit,
removing the ice chips and, then restarting the appliance.
Please restart the ice maker by pressing the ON/OFF button. If the ice shovel does not
push the ice into the ice basket after ice drops from on the avaporator rods and the ICE
indicator in the middle of the control panel is illuminated, check to see if the water tray
is horizontal and balanced. If it is not, adjust it by pressing the ice shovel lightly with
your finger. Then restart the ice maker.
PROBLEM
The compressor functions
abnormally and makes a
buzzig noise.
low water indicator light is
illuminated
Indicator lights on display
are not illuminated.
POSSIBLE CAUSE
The voltage is lower than
recommended.
1�There is no water.
2�The pump has an air
blockage.
Blown fuse / no power.
47
SUGGESTED SOLUTIONS
Stop the ice maker and
do not restart it until the
voltage is correct.
1� Press ON/OFF button
the stop button, fill with
water, wait 3 minutes and
press ON/OFF button to
restart. When the water
has reaches the water level
indicator, the ice maker will
restart automatically.
2� Remove the silicon stop-
per and let several drops of
water run out.
Replace the fuse / Turn the
power on.
GB