CommIssIoNINg
Switching on and off
CAuTIoN: Electric tools and compressed air tools must be switched off when
they are connected.
The plug socket on the vacuum cleaner will always be live when the mains plug is
plugged in, irrespectively of the position of the switch.
NOTE: If the switch is in the >0< position, the plug socket on the vacuum cleaner
can be use as an extension lead.
Connection value: Vacuum cleaner + connected unit, maximum 16 A.
Insert the plug into socket
0
Vacuum cleaner is switched off
I
Vacuum cleaner switched on without shaker function
Vacuum cleaner on standby
Vacuum cleaner switched on without shaker function
A
Ready mode for ON/OFF automatic mode.
(Suction unit is switched ON/OFF by the electrical tool)
Vacuum cleaner on standby
Ready mode like "A" plus automatic filter cleaning.
AC
The vacuum cleaner only switches on when the tool is switched on.
After the tool is switched off, the vacuum cleaner runs on for approx. 10 sec
to prevent any residue from collecting in the hose.
Set the vacuum cleaner to the switch position >0<.
Pull out the plug after you have finished.
Fix the suction hose in the accessory storage location* on the back of the container
for storage.
The ends of the hose can be pushed into each other to prevent particles of dirt from
coming out.
selector switch for minimum material flow (horn and light)
CAuTIoN:
on vacuum cleaners classes "m" and "H"
In the modes >AC< and >A< the following setting is made, depending on the
diameter of the hose:
Inside diameter of the hose
Ø 35 mm
Ø 27 mm
Ø 21 mm
No speed regulation is carried out. The vacuum cleaner always runs at max. speed.
Switch position
70 m³/h
40 m³/h
20 m³/h
GB