Interlogix DD1012AM Mode D'emploi page 7

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
Green mode
When SW1-5 is set to Remote on, the radar is switched off
during the day mode (with no WT) to reduce current
consumption. The detector is then operating in PIR only mode.
Note:
The Day/night line must be connected to the control
panel for this mode to work.
Alarm memory
When SW1-5 is set to Remote on, alarms that occurred during
the night mode are stored in the detector memory. They are
indicated by flashing red LED when the unit switches to day
mode (walk test disabled). The memory is cleared when the
detector switches back to the night mode.
Note:
Set SW1-6 to Off to prevent showing the alarm memory
on the LEDs. See "SW1-6: LEDs" on page 6.
LEDs and outputs
To enable LEDs functionality, set SW1-6 to On, otherwise
LEDs are disabled in any condition. See "SW1-6: LEDs" on
page 6 for more details.
Table 6: LEDs and outputs
Status
Red
Yellow
LED
LED
Start up
Low voltage
PIR intruder
alarm
Microwave
intruder alarm
Dual motion
intruder alarm
Dual Alarm
Memory
AM alarm
Technical fault
Continuously on
Normal blinking (1 Hz)
Specifications
Detector technology
Range
Viewing angle
PIR optics
Microwave frequency
Maximum power output
Maximum microwave output at 1 m
Memory function
Input power
Peak-to-peak ripple immunity
Detector start-up time
P/N 146666999-1 (ML) • REV G • ISS 19AUG19
Alarm
Fault
To reset
relay
relay
Closed
Closed
Automatically
after 60 s
Open
Open
Apply correct
voltage
Closed
Closed
Closed
Closed
Open
Closed
Automatically
after 3 s
Closed
Closed
Switch to the
night mode
Depends
Open
Depends on
on SW2-4
SW2-3
Closed
Open
Successful walk
test
Dual+AM
4, 6, 9, 12 m selectable via
SW1-1 and SW1-2
78 degrees
9 high-density mirror curtains
5725 to 5875 MHz
13.46 mW
0.003 μW/cm²
Yes
9 to 15 V
(12 V nominal)
2 V (at 12 V )
60 s
Current consumption
Mounting height
Target speed range:
DD1012AM
DD1012AM-D
Alarm (NC) / Tamper relay
characteristic
Fault relay characteristic
Alarm time
Operating temperature
Relative humidity
Weight
Dimensions (H x W x D)
IP/IK rating
Pry-off tamper
Regulatory information
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR SALE
and disclaimers
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY "AUTHORIZED
DEALER" OR "AUTHORIZED RESELLER", IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/
Certification
UTC Fire & Security hereby declares that this
device is in compliance with the applicable
requirements and provisions of all applicable rules
and regulations, including but not limited to the
Directive 2014/53/EU. For more information see:
www.utcfssecurityproducts.eu
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.recyclethis.info
Contact information
www.utcfireandsecurity.com or www.interlogix.com
For customer support, see www.utcfssecurityproducts.eu
10 to 22 mA (11 mA nom.)
2 to 2.6 m (6.6 to 8.5 ft.)
0.2 to 3.0 m/s (8 in./s to 10 ft./s)
0.1 to 4.0 m/s (4 in./s to 13 ft./s)
80 mA 30 V , Form A
80 mA 30 V , Form A
3 s
−10 to +55°C (14 to 130°F)
95% max. noncondensing
120 g
126 × 63 × 50 mm
IP30 IK04
Yes