Important; Use And Calibration - Fiem libretto smart 2010 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The incubator has a single-phase electric cable (of 1,5-2 mt. approx) with a plug to lacing to electric energy
230V, 50-60 Hz.
On the back side, the data label informs the absorption and the power of the incubator.
IMPORTANT: Remember to check the correct thermometer working, seeing that there is not interruption on
mercuric line.
WARNINGS:
The incubator must be connected to a net supply with earth connection.
Take off the electric plugs before cleaning operations.
If the electric cable with plug is damaged, it must be replaced by the manufacture or by Technical assistance
service or by authorized personal to be prevented any risks.
The electric cable with plug should not be accessible to the animals. Empty water basins before to move the
incubator. Do not use the incubator if damaged.
POSITIONING, LACING AND PREPARATION
The local where machine is placed, shall be enough aired and dry, at a constant temperature between 18-25 °C.
Place the incubator on a plan surface not tilted and possibly near to an electric intake of easy access. For a
net supply, use only the electric plugs supplied with earth connection.
ADVICE: The builder declines every responsibility in case of any improper use or improper placement, connec-
tion to any authorized apparatus or tampering from not authorized personal.
Insert the thermometer into the plastic clip on top of the support of the eggs wire net, paying attention to do
not break it and regulate it with its bulb at the middle line of the eggs.
• Before using the machine, remember to clean carefully the machine inside and outside, as showed in para-
graph n° 6.
EGG-TURNING KIT ASSEMBLING:
The egg-turning kit allows the eggs to be turned automatically by a horizontal movement of the plastic grid pla-
ced on the wire net, this movement is slow and delicate. The egg-turner motor is placed inside plastic box atta-
ched lateral to the inferior part of the machine and it is insulated and protected by a plastic cover.
Connect the plug to an electric intake of easy access and make sure that moving starts; please note that egg-
turner motor does 1 rp clockwise direction of 360° per hour which is transformed in linear movement go and
back each of 30 minutes.
If the incubator is manual for turning eggs, remember to turn the eggs by the rod of the grid one time go and
one time back twice per day (morning and evening).
ATTENTION: Inside egg-turner plastic box there is electric tension 220/230V, so before to open the
box for any possible checking, make sure that plug is not connected to electric network.

USE AND CALIBRATION

For the switching on the machine connect the electric plug to the electric network and before to load the
eggs await for the incubator has reached the working temperature of 100°F(37,7°C). Positing gradually the
ready eggs for the incubation on the wire net, only when the incubator has reached the working temperatu-
re of 100°F.
Loading the eggs conserved not later then 7- 8 days and not earlier then 3 days from deposition -
before the incubation, the eggs must be conserved in a local with temperature between 14 – 16 °C.
On the upper part, it is placed the analogical thermostat, ( which has been set-up by the factory, when it is
working, the green led results light, the continuous or intermittent lighting of the red led points out the activa-
tion of the heating.
We recommend to pay attention to the mercuric thermometer, which has to mark 100°F (37,7°C), always in a
precise way.
1
It is important to remind that the local conditions where the machine is placed (temperature, humidity and aeration) do not influence sen-
sibly on the temperature inside the unit while can condition not indifferently the inside humidity values.
1
11

Publicité

Table des Matières
loading

Table des Matières