D
broken ignition coil
D
ADJUSTING THE FLAME
After you have ignited the heater, it will take 10 to 15 minutes for the flame to
become visible in the combustion chamber. Only then can you check whether the
flame is correct. Too high a flame may cause smoke and soot, whereas too low a
flame causes smells. The page opposite the folding page shows the minimum and
maximum permissible burning heights of the flame (Fig. M). The flame can be
adjusted with the wick adjuster knob · (Fig. H).
Too low a flame may also be caused by:
insufficient fuel
poor fuel quality
insufficient ventilation
wastage of the wick
E
SWITCHING OFF THE HEATER
Turn the wick adjuster knob counter clockwise until it stops (about 1/8 turn)
(fig. J.). After a few minutes continue turning counter clockwise until it stops
(about a half turn). Within a few moments the flame will be completely extinguis-
hed and the heater will be off.
NOTE: For routine turn-off, DO NOT use the "Manual Shutoff" or activate the
"Automatic Extinguisher" by jarring the heater. These methods may cause
unwanted odour, soot and smoke. Only the wick adjuster knob should be used
for normal shutoff.
F
MALFUNCTION, CAUSES AND SOLUTIONS
If any malfunctioning cannot be solved from the directions below, please contact
your Zibro dealer.
THE HEATER DOES NOT IGNITE
The batteries are not positioned correctly in the holder. Check (Fig. D).
There is not enough power left in the batteries for the ignition. Replace (Fig. D).
You have run out of fuel from the tank or the wick has been replaced.
After having refilled and replaced the fuel tank, wait for 30 minutes
before igniting the heater.
You are pushing down the igniter slide » with too much force.
Push it down less forcefully (Section C).
The ignition coil
Contact your dealer.
(fill the tank)
(contact your dealer)
(leave window or door ajar)
(contact your dealer or replace the wick,
refer to section L)
is defective.