Installing the A2C-SC IntelliFlow
NOTICE
Do not over-tighten nuts.
To avoid cross threading, check thread alignment.
9.
Connect the washing machine hoses to the IntelliFlow's hot and cold water outlets.
10. Plug the washing machine into the IntelliFlow's electrical outlet.
NOTICE
Appliance current rating must not exceed 15 amps.
11. Plug the IntelliFlow's power cord into the electrical receptacle that has been turned off
(Figure 4).
NOTICE
The IntelliFlow requires a 120VAC, 60Hz, 15 amp ground-fault protected receptacle.*
12. Install leak sensor.
*Ground Fault Interrupter – A GFI circuit is not required for proper operation of the
IntelliFlow, but is strongly recommended as a safety device.
NOTICE
The IntelliFlow will detect any current flow to the washing machine when the washing
machine is off. During startup or at any time during troubleshooting, the IntelliFlow valve can
be reset to OFF condition by unplugging and reinstalling the leak sensor.
13. Turn on both hot and cold water supply lines, and check for leaks.
14. If there are no leaks, make sure the hoses are connected and turn the electrical power
back on.
15. Installation/activation procedure for connected IntelliFlow.
NOTICE
Do not plug valve into electrical supply circuit until you have completed installing
the unit and reconnecting the water supply lines.
8
IS-A2C-SC-IntelliFlow
Watts
A2C-SC
Washer
Figure 4
2122
®
Power supply
ground fault
protected
Water supply
© 2021 Watts