Replace The Fuse - Vollrath MPI4-1800S Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

REPLACE THE FUSE

The Troubleshooting section of this manual describes situations in
which the fuse may need to be replaced.
Tools You Will Need
• Small screw driver
• Towel or soft cloth
• 314 20A fuse (Available on Vollrath.com and found at most
hardware stores)
1. Turn off and unplug the induction range.
2. Place a towel or soft cloth on a flat, stable surface.
3. Gently and carefully, lay the induction range, glass-side down, onto
the towel. Locate the fuse cap.
4. Using the screwdriver; press down and turn the fuse holder cap to
release it from the range.
5. Remove the fuse from the holder.
6. Insert a replacement fuse into the holder.
7. Re-insert the holder and use the screwdriver to secure the cap into
the range.
8. Ensure the cap holder is locked into place.
Medium Power Countertop Induction Ranges with Temperature Control Probe Operator's Manual
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mpi4-1440s

Table des Matières