Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Activation/Deactivation of Partial Inversion on Open
Activation/Deactivation of Follow-Me
Operation test
Assign a text string for each photocell
Set the MODE (operation) of each photocell
Key switches
Operation test
Assign a text string for each I/O Interface
Set the MODE (operation) of each I/O Interface
Flashing lights
Enable/Disable Pre-Flash on Closing
Enable/Disable Pre-Flash on Opening
Enable/Disable Fast Flash on Opening
Enable/Disable Fast Flash on Closing
Enable/Disable Flash on Pause
Operation test
Assign a text string for each flashing light
I/O Interface
Operation test
Assign a text string for each I/O interface
Set the MODE (operation) of each I/O interface
Utility output
Set Electric lock activation time
Diagnostics
Display the number of Manoeuvres Performed
Display the number of Operator Hours of operation
Display the number of System Life Hours
Display the number of Resets
Display the number of Stops
Display the number of Encoder notches
FACTORY RESET
If there is need to restore the control unit to its factory settings, press
simultaneously the RESET, TX CODE, AUTOSET and STEP BY STEP
buttons, release only the RESET button (holding the others pressed), until
the AUTOSET led begins to flash. Now you can release the other buttons
(TX CODE, AUTOSET and STEP BY STEP), and the TX CODE led begins
to flash . Once TX CODE led stop flashing, wait until the AUTOSET led turns
on for a while and then its turning off will confirm the control unit resets all
parameters to their initial factory settings.
DIAGNOSTICS
Management of photocells (DS) in the event of faults
The photocell management (DS) in case of a fault of AT LEAST ONE OF
THOSE ACQUIRED during installation will INHIBIT CLOSING of the barrier
(excluding all cases of controlled or automatic closing). If a photocell
previously acquired experiences a fault, the automation will stop and will only
be able to open (for safety reasons), but will never be able to close, except
following:
1. Disabling of the safety devices (DS) via the DIP switch #10 (ON)
2. Reacquisition of the missing DS (with the same ID of the faulty device)
Disabling of the safety devices (emergency operation)
Disabling management of the DS (photocells, stops, etc.) allows the control
unit to "logically eliminate" the DS that are faulty/missing, but continuing
to manage consistently the settings of the functional DS installed on the
system. Essentially, disabling the safety devices (DS) does not eliminate the
photocells installed and that are functional (raising safety issues), but only
those that are no longer functional.
Reacquisition of the missing DS (fault repair)
If a photocell (DS) experiences a fault, the automation operates according
to the function set on the faulty DS (e.g.: if the photocell is set ON OPEN
when the barrier experiences a fault , the barrier stops and will not restart until
disengaged, which will never occur, due to the presence of the fault). If you
do not want to intervene by disabling the DS via DIP switch #10, you will have
to repair the fault, i.e. replace the faulty DS with an equivalent one having the
same ID. Once you have reconnected the repaired DS, you have to run the
(DETECT) procedure again by:
a. Pressing the RESET button in the control unit
b. running DETECT via the COMUNELLO ONE app
CAUTION: when pressed, the RESET button detects all accessories
present, and re-reads all HW parameters on the board (trimmer settings,
DIP, SLIDE etc.) and SETS THE FIRST MANOEUVRE TO OPENING. If the
barrier is already fully open (safety manoeuvre), this may generate a block
on opening and the need for another command to activate closure of the
barrier.
BLACK-OUT MANAGEMENT
In the event of a power failure (or following the logic RESET, i.e.: pressure of
the key RESET on control unit), the system always makes a short opening
manoeuvre, followed by a closing manoeuvre in safety speed (receiving the
following command).

WARRANTY

Fratelli Comunello SpA provides a warranty for 24 months for the correct
functioning of the actuators from the date of manufacture, provided that the
performance specications indicated in the product instruction manuals are
respected. Free of charge repair and replacement of components that are
found to be faulty according to the indisputable judgment of the company's
technical staff shall be guaranteed at the sole discretion of Fratelli Comunello
Spa, and so excluding any claim for damages made by others. Warranty
material shall be returned to Fratelli Comunello S.p.a. headquarters carriage
(1"..20")
paid and will then be shipped to the customer carriage unpaid. The material
found to be faulty and returned to Fratelli Comunello S.p.a. shall remain
property of the Seller. Any cost resulting from any work needed to repair
the defect or to replace the material shall be charged to the Buyer. No
compensation shall be allowed for the period of device inactivity. Work under
warranty does not prolong the warranty period. The defect of the product
shall be reported by the Buyer within 8 (eight) days from its discovery or
from the date of delivery of the goods, under penalty of invalidation of the
warranty. Such claim shall be notied in writing.
Warranty does not cover:
Any product defect or damage that may have been incurred during
transport; any defect or damage arising from any fault and/or from neglect,
inadequacy and misuse of the electrical wiring in the Buyer's property; any
defect or damage caused by any repairs carried out by non authorised
personnel or by incorrect use/installation (with reference to this, system
maintenance is recommended every 6 months) or if not original spare parts
are used; any defect caused by chemicals or atmospheric conditions. The
warranty does not cover any cost neither for consumable materials nor for
alleged defects or convenient surveys.
Product Features Fratelli Comunello SpA products are subjected to
continue changes and improvements; their technical features and image
may therefore change without previous notice.
Competent court
Since the contract of sale is conrmed by an Order Conrmation drawn up
in Rosà, any such dispute shall be settled by the laws of Italy and by the
court of Vicenza (VI)
COMUNELLO ®Copyright 2015 - All right reserved
47

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Limit 600 oneLimit 800 one

Table des Matières