Warranty - Comunello Automation BORDER 400 Instructions D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EXTENDED MENU 3
The control unit is factory set to allow direct selection exclusively of the main
menu functions.
If you wish to enable the functions described in Extended Menu 3, proceed
as follows: select blinking LED no. 8 and press SET 3 times. The LED will
start blinking alternately 1 1 1 0 1 1 1 0 1 1 1 0. This means there is a
period of 30 seconds to select the functions in Extended Menu 3 using the
SEL and SET keys and then, after a further 30 seconds, the control unit will
revert to the main menu.
level
L1
1
L2
2
L3
3
L4
4
L5
5
LED 1 + LED 2 +LED 3 +LED 4 +LED 5
L6
6
LED 1 + LED 2 +LED 3 +LED 4 +LED 5 + LED 6
L7
7
LED 1 + LED 2 +LED 3 +LED 4 +LED 5 + LED 6 + LED 7
LEV
Menù
DECELERATION FORCE ADJUSTMENT:
Operator force during the deceleration stage can be programmed on the
control unit. You can select one of 7 different power levels as follows; ensure
you have enabled Extended Menu 3; each combination of lit LEDs defines
a level as shown in the above table; in practice, starting from the bottom
LED (LED 1) and proceeding upward, each additional LED corresponds to
a higher power level. Use the SEL key to scroll through the different power
levels; for each selected power level the top LED will blink (for example,
selecting level 4, LED 1 + LED 2 + LED 3 will be steady on, while LED 4 will
blink); press SET to confirm. Factory setting: level 3 selected.
RESET
If you need to reset the control unit to restore the factory settings, press the
SEL and SET keys together; this will cause all the RED indicator LEDs to
light simultaneously followed immediately by the control unit switching off.
WARNING: restoring factory settings does not include deletion of all
previously saved Remotes and resetting of the first remote rule logic.
DIAGNOSTICS
Photocell Test:
The control unit is prearranged for connection of safety devices in
compliance with standard EN 12453 point 5.1.1.6. At each operating
cycle, a functional test of the connected photocell is performed. In the case
of an open circuit and/or malfunctioning of the photocell, the control unit
does not enable movement of the barrier and visually signals the test failed
condition by causing all the indicator LEDs to blink simultaneously. As soon
as correct operation of the photocell is restored, the control unit is ready for
normal use. This operating mode guarantees fault monitoring in compliance
with EN 954-1 Category 2.

WARRANTY

Fratelli Comunello SpA provides a warranty for 24 months for the correct
functioning of the actuators from the date of manufacture, provided that the
performance specications indicated in the product instruction manuals are
respected. Free of charge repair and replacement of components that are
found to be faulty according to the indisputable judgment of the company's
technical staff shall be guaranteed at the sole discretion of Fratelli Comunello
Spa, and so excluding any claim for damages made by others. Warranty
material shall be returned to Fratelli Comunello S.p.a. headquarters carriage
paid and will then be shipped to the customer carriage unpaid. The material
found to be faulty and returned to Fratelli Comunello S.p.a. shall remain
property of the Seller. Any cost resulting from any work needed to repair
the defect or to replace the material shall be charged to the Buyer. No
compensation shall be allowed for the period of device inactivity. Work under
warranty does not prolong the warranty period. The defect of the product
shall be reported by the Buyer within 8 (eight) days from its discovery or
from the date of delivery of the goods, under penalty of invalidation of the
warranty. Such claim shall be notied in writing.
Warranty does not cover:
24
COMUNELLO ®Copyright 2015 - All right reserved
EXTENDED MENU 3
LED ON
LED 1
LED 1 +LED 2
LED 1 +LED 2 +LED 3
LED 1 + LED 2 +LED 3 +LED 4
3 Flashes
Any product defect or damage that may have been incurred during
transport; any defect or damage arising from any fault and/or from neglect,
inadequacy and misuse of the electrical wiring in the Buyer's property; any
defect or damage caused by any repairs carried out by non authorised
personnel or by incorrect use/installation (with reference to this, system
maintenance is recommended every 6 months) or if not original spare parts
are used; any defect caused by chemicals or atmospheric conditions. The
warranty does not cover any cost neither for consumable materials nor for
alleged defects or convenient surveys.
Product Features Fratelli Comunello SpA products are subjected to
continue changes and improvements; their technical features and image
may therefore change without previous notice.
Competent court
Since the contract of sale is conrmed by an Order Conrmation drawn up
in Rosà, any such dispute shall be settled by the laws of Italy and by the
court of Vicenza (VI).