EN
A22KPOE Wiring Diagram
From PoE+ source
(Data + Power)
Ethernet @ 10/100 Mbps
Maximum 100m (300ft.)
Furthest RS485 module at
maximum 1220m (4000 ft).
RS485 Port
The RS485 port is used to connect
and communicate with an A22K set
as "Expander" or any RS485
ATRIUM modules.
Up to 4 A22K set as "Expander"
can be connected per RS485 port.
We highly recommended to use a
twisted pair wiring as shown below.
It will avoid any communication
problem that may occur in noisy
environments.
A22K
RS485 port
connector
+12V DC (Not use)
A+
B-
The pre-assembled PoE+ Splitter
seperate data and power coming
from PoE+ source, example:
PoE+ switcher or injector
PoE+ Splitter
DC power output
POES
ETHERNET
ETHERNET
PORT
+12V DC
RS485
LOCAL
A+
BUS
B-
Input 1
EXTRA
Input 2
INPUTS/
Output 1
OUTPUTS
+12V DC
Output 2
READER DOOR 1
READER DOOR 2
BUZ GRN RED D1
D0 GND 12V
BUZ GRN RED D1
D0 GND
Contrôleur 2 portes
Ethernet Port
(Data)
(24 Vdc)
LOCAL BUS
24V DC INPUT/
STATUS
LOCK 1 & 2
BATTERY/
JUMPER SETTING
MODULE TYPE
SYSTEM STATUS
ENCLOSURE
TAMPER
INPUT
INPUT
SWITCH
DOOR 1
DOOR 2
INPUT
12V
C1
GND
REX1
12V
C2
GND
REX2
12V
GND
TMP
LK1+ LK1-
A22K
Power Over Ethernet
INPUT
+24V DC
POWER
-
SUPPLY
Power Supply
LED Indicator
BATTERY
+12V DC
BACKUP
-
LOCK
LOCK
DOOR 1
DOOR 2
C1 NO1 NC1
LK2+ LK2-
C2 NO2 NC2
55