For power supply: 230V 50Hz
(Customer prepare)
Power Supply
230V 50Hz
Earthing
Note:
Must be hard wired, no plug allowed.
The swimming pool heater must be earthed well.
3. Electric Wiring Diagram
Options for protecting devices and cable specification
MODEL
Rated Current A
Breaker
Action Current mA
Fuse
Power Cord
Signal cable
※ Above data is subject to modification without notice.
Note: The above data is adapted to power cord ≤ 10m. If power cord is>10m, wire
diameter must be increased. The signal cable can be extended to 50m at most.
4. Installation instruction and requirement
The heat pump must be installed by a professional team. The users are not qualified
to install by themselves, otherwise the heat pump might be damaged and risky for
users' safety.
Distribution Box
Fuse
Breaker
BPNR06
Rated Residual
A
2
(mm
)
2
(mm
)
Swimming Pool Heat Pump Wiring Board
Power Cord
BPNR08
8.0
8.0
30
30
8.0
8.0
3×1.5
3×1.5
3×0.5
3×0.5
8
BPNR10
9.5
30
9.5
3×1.5
3×0.5