Programming; Adjusting The Flush Duration; Reset - DURAVIT Utronic Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33

5.4 Programming

5.4.1
S3: Adjusting the flush duration
Refer to page 2 for a graphic illustration of program selection.
>
Hold the magnetic key in front of the right signal eye until 6 signal tones sound,
with a longer interval between the 5th and 6th signal tones (approx. 6 sec.).
>
Remove the magnetic key.
The control confirms the program selection by 2 short signal tones.
>
Hold the magnetic key in front of the right sensor eye again within 4 sec.
Flushing starts. A signal tone sounds at a 1 second interval at the same time.
>
Leave the magnetic key in front of the right signal eye (min. 5 sec., max. 20 sec.)
until the desired flush duration has been set.
>
Remove the magnetic key
The control confirms the setting for the new flush duration by 2 short signal
tones.
The flush duration has been changed.
Finally, the control reactivates the preset flushing program.
5.4.2
S4: Reset
Refer to page 2 for a graphic illustration of program selection.
>
Hold the magnetic key in front of the right signal eye until 7 signal tones sound,
with a longer interval between the 5th and 6th and the 6th and 7th signal tones
(approx. 6 sec.).
>
Remove the magnetic key
The control confirms the program selection by 2 short signal tones.
>
To initiate reset, hold the magnetic key in front of the right sensor eye again within
the next 4 sec.
The control confirms the reset by 2 short signal tones.
>
Remove the magnetic key.
The control unit has now been reset to the factory settings (defaults).
>
Start up the control unit again as described in section 5.1.
28

Publicité

Table des Matières
loading

Table des Matières