Beta 960TP Mode D'emploi page 11

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
SPECIFICATIONS
Sensor type
Sensor output
Sensor FS.
Proof pressure
Resolution
Accuracy
Battery type
Display type
Display backlight
Wireless printing module
Adaptors included
Functions included in programme : - Oil pressure test
TESTER SETUP
The 960TP uses English as default language and BAR as default pressure standard.
If you need to change these parameters, you should enter into the setup mode. You can enter the
setup mode pressing the OK button (3) when you turn on the tester.
When you enter the setup mode, you can change the language using the up and down arrow. When
you see your language on the display, press OK to confirm.
After the user has confirmed the language, the tester will ask if you need to measure BAR or PSI.
Change your selection using the up and down arrows; press OK (3) to confirm.
: Strain gauge technology, amplified and digital temperature
compensation
: Ratiometric. 0.5 ÷ 4.5 V DC at 5V DC excitation
: 80 bar / 1160 PSI
: 150% FS
: 0.1 bar / 1 PSI
: 1% FS (0º ÷ 50 ºC)
: 9V
: 60x128 pixel LCD
: Yes
: 868 MHz (ISM unlicensed band)
: 6 mm and 8 mm
- Petrol compression test
- Diesel compression test
- 80 bar manometer
- Petrol injection pressure test
- Low side common rail test

Publicité

Table des Matières
loading

Table des Matières