Page 1
Reversible operator with regulation of self-registering run stops for rolling shutters balanced with springs Operador reversible con regulación del final de carrera regulador automático para puertas enrollables equilibradas con muelles JOLLY BIG ONE JOLLY BIG TWO Scarica questo manuale sul tuo cellulare Disegni tecnici per progetti Téléchargez ce manuel sur votre mobile...
IMPORTANTI ISTRUZIONI PER LA SICUREZZA INSTRUCTIONS IMPORTANTES POUR LA SECURITE ATTENZIONE - PER LA SICUREZZA DELLE PERSONE È IMPORTANTE CHE VENGANO SEGUITE TUTTE LE ISTRUZIONI ATTENTION - POUR LA SECURITE DES PERSONNES, IL EST IMPORTANT DE SUIVRE TOUTES LES INSTRUCTIONS CONSERVARE CON CURA QUESTE ISTRUZIONI CONSERVER SOIGNEUSEMENT CES INSTRUCTIONS 1°...
Page 3
IMPORTANT INSTRUCTIONS FOR THE SAFETY IMPORTANTES INSTRUCCIONES PARA LA SECURIDAD ATTENTION - FOR THE SAFETY OF PEOPLE IT IS IMPORTANT TO FOLLOW ALL THE INSTRUCTIONS ATENCIÓN PARA LA SEGURIDAD DE LAS PERSONAS ES IMPORTANTE QUE SE OBSERVEN TODAS LAS INSTRUCCIONES CONSERVAR CUIDADOSAMENTE ESTAS INSTRUCCIONES KEEP THESE INSTRUCTIONS WITH CARE 1°...
CARATTERISTICHE TECNICHE / INSTALLAZIONE JOLLY BIG CARATTERISTICHE TECNICHE / INSTALLAZIONE JOLLY BIG CARATTERISTICHE TECNICHE JOLLY BIG ONE JOLLY BIG TWO Motori elettrici N° Peso max. serranda Superficie max. serranda Capacità di avv.to finecorsa N° giri Coppia nominale di funzionamento Coppia massima di lavoro...
Page 5
COME INSTALLARE JOLLY BIG CON ELETTROFRENO IMPORTANTE: Prima di installare JOLLY BIG, controllate che la serranda sia correttamente bilanciata dalle molle montate sul palo. Verificatelo manualmente aprendo e chiudendo la serranda. Asola Ø 12 mm (entrata del cavo dello sblocco) Foro Ø...
COLLEGAMENTI ELETTRICI Questa istruzione è valida solo se l’operatore viene collocato sul palo della serranda con il motore rivolto a destra (visto dall’interno del fabbricato). ATTENZIONE: Se l’operatore viene montato con il motore rivolto a sinistra (visto dall’interno del fabbricato), i movimenti dell’operatore e quindi dei finecorsa vengono invertiti.
Collegate il cavo di alimentazione agli appositi morsetti. ATTENZIONE: Eseguire i collegamenti come da schema sottostante (pulsante APRE con morsetto OPEN, pulsante CHIUDE con morsetto CLOSE e al morsetto COM collegare la fase diretta dell’alimentazione. PUSH BUTTON POWER SUPPLY CLOSE OPEN CLOSE OPEN...
Page 8
REGOLAZIONE FINECORSA AUTOMATICO (BREVETTATO) A - Chiudere la serranda manualmente. B - Verificare che l’interruttore sia su INS. C - Assicurarsi che la camme C1 sia appoggiata al seeger S1 e se così non fosse spostate la levetta della camme C1 e ruotate la camme contro il seeger S1.
Page 9
Per i collegamenti ed i dati tecnici degli accessori attenersi ai relativi libretti di istruzione. QUADRI ELETTRONICI FUNZIONI DEL QUADRO ELETTRONICO MINI MINI - cod. ABQM090 Gestione 1 JOLLY BIG ONE ACCESSORI COLLEGABILI Funzionamento a uomo presente (apre - chiude) Pulsantiera FLAT...
Page 10
FUNZIONI DEL QUADRO ELETTRONICO R-CRX 2.0 R-CRX 2.0 230/50-60Hz cod. ABJ8042 • Tempo di lavoro regolabile o infinito • Funzionamento impulsivo o a uomo presente in apre e/o in chiude. • comandi direzionali apre (con gestione orologio) e chiude • comando di stop •...
Page 11
J-CRX 230V 50-60Hz - cod. ABJ7080 J-CRX 120V 60Hz - cod. ABJ7079 Gestione 1 JOLLY BIG TWO Gestione 2 JOLLY BIG ONE montati sulla stessa serranda (lavora un solo gruppo di finecorsa) Funzionamento a tempo Chiusura automatica Funzionamento passo-passo o automatico...
Page 12
CASSAFORTE VECOR FLAT - Scatola da incasso tipo 502E non inclusa - Pulsante saliscendi e inseritore allarme non inclusi Contenitore di sicurezza per impedire l’agibilità ai dispositivi di comando. Viene fornita di serie completa di sblocco elettrofreno e spazio per 2 moduli in scatola incasso tipo 502E.
Page 13
FIT SLIM EN12978 - EN13849-2 SAIL FOTOCELLULE DA PARETE cod. ACG8032B 102.5 47.5 COPPIA DI COLONNINE PER FIT SLIM cod. ACG8065 Le fotocellule FIT SLIM hanno la funzione di sincronismo in corrente alternata e portata di SAIL arancio con scheda intermittente incorporata cod.
CARACTERISTIQUES TECHNIQUES / INSTALLATION JOLLY BIG CARACTERISTIQUES TECNIQUES JOLLY BIG ONE JOLLY BIG TWO Moteurs électriques N° Poids maxi du rideau Surface maxi de rideau Capacité du fin de course N. vitesse Couple nominal de fonctionnement Couple maxi operatifs Force maxi de soulevement de terre...
COMMENT INSTALLER LE JOLLY BIG AVEC ÉLECTROFREIN IMPORTANT: Avant l’installation du JOLLY BIG, contrôler que le rideau soit équilibré correctement par les ressorts montés sur l’arbre. Vérifier manuellement en ouvrant et en fermant le rideau. Trou Ø 12 (pour vis TE10x140) Boutonnière Ø...
BRANCHEMENTS ÉLECTRIQUES Ces instructions ne sont valables que si l’opérateur est placé sur le poteau du portail avec le moteur tourné à droite (vu de l’intérieur du bâtiment). ATTENTION: Si l’operateur est monté avec le moteur tourné à gauche (vu de l’intérieur du bâtiment), les mouvements de l’opérateur et donc des fins de course sont inversés.
Page 17
Connecter le câble d’alimentation aux bornes à cet effet. ATTENTION: Exécuter les connexions selon le schéma ci-après (bouton OUVRE avec borne OPEN, bouton FERME avec borne CLOSE et connecter la phase directe de l’alimentation à la borne COM). PUSH BUTTON POWER SUPPLY CLOSE OPEN...
REGLAGE FIN DE COURSE AUTOMATIQUE (BREVETE) A - Fermer le portail manuellement. B - Vérifier que l’interrupteur soit sur INS. C - S’assurer que la came C1 soit appuyée au seeger S1 et elle n’y était pas appuyée, déplacer la manette de la came C1 et tourner la came contre le seeger S1.
Pour les branchements et les données techniques des accessoires, se conformer aux livrets d’instruction correspondants. COFFRETS ELECTRONIQUES FONCTIONS DES COFFRET ELECTRONIQUE MINI MINI - code ABQM090 Gestion 1 JOLLY BIG ONE ACCESSOIRES RACCORDABLES Fonctionnement homme presente (ouverture - fermeture) Bouton-poussoir FLAT...
FONCTIONS DES COFFRET ELECTRONIQUE R-CRX 2.0 R-CRX 2.0 230/50-60Hz cod. ABJ8042 • adjustable or infinite operating time • pulsed or dead man operations in opens and/or closes. • directional open - close commands • stop command • radio commands - step by step (open - stop - close) or automatic (open - close) •...
J-CRX 230V 50-60Hz - code ABJ7080 J-CRX 120V 60Hz - code ABJ7079 Gestion 1 JOLLY BIG TWO Gestion 2 JOLLY BIG ONE monté sur la même portail (fonctionne uniquement un groupe de fin de course) Fonctionnement en mesure Fermeture automatique Fonctionnement pas-à-pas ou automatique...
COFFRE-FORT VECOR FLAT - Boîte de derivation type 502E non inclue - Bouton ouvre- ferme et déclenchement de l’alarme non inclus Coffret de sécurité empêchant tout accès non autorisé aux dispositifs de commande. Fourni de série d’un dispositif de déblocage de l’électro-frein et de l’espace pour 2 modules en boîte encastrable type 502E.
FIT SLIM EN12978 - EN13849-2 SAIL PHOTOCELLULES MURALES code ACG8032B 102.5 47.5 PAIRE DE POTEAUX POUR PHOTOCELLULES code ACG8065 Les photocellules FIT SLIM ont la fonction de synchronisme dans le courant à C.A. et les SAIL orange avec panneau clignotant intégré code ACG7072 gammes de 20 m.
TECHNICAL DATA / INSTALLATION JOLLY BIG TECHNICAL DATA JOLLY BIG ONE JOLLY BIG TWO Electric motors N° Max gate weight kg/lbs 280/617 450/992 Max gate surface Limit switch winding capacity N. rotat. Nominal functioning torque Max operating torque Max lifting force from earth...
Page 25
HOW TO INSTALL JOLLY BIG WITH ELECTROBRAKE IMPORTANT: Before install JOLLY BIG check that the shutter is correctly balanced by screws mounted on the shaft. Verify it manually by opening and closing the shutter. Buttonhole Ø 12 mm / 0,47 in (entry of the release cable) Hole Ø...
ELECTRIC CONNECTIONS These instructions are only valid if the operator is located on the support of the shutter with the motor facing to the right (as seen from the inside of the building). CAUTION: If the operator is assembled with the motor facing to the left (as seen from the inside of the building), the movements of the operator and therefore of the run stops are reversed.
Page 27
Connect the power supply cable to the clamps provided. CAUTION: Make the connections according to the chart below (OPEN button with OPEN clamp, CLOSE button with CLOSE clamp and connect the direct phase of the power supply to the COM clamp).
Page 28
REGULATION OF AUTOMATIC RUN STOPS (PATENTED) A - Close the shutter manually. B - Verify that the switch is on INS C - Ensure that cam C1 is resting on Seger S1 if it is not then move the lever of the cam C1 and turn the cam against Seger S1. D - VERY IMPORTANT ! Remove Seger S1 (Hold Seger S1 for future adjustments).
Check that the springs are properly balanced and lubricate the guide with silicone grease. OPTIONALS For the connections and the technical data of the fixtures follow the relevant handbooks. CONTROL PANELS MINI ELECTRONIC CONTROL PANEL FUNCTIONS MINI - code ABQM090 Control of 1 JOLLY BIG ONE Functioning with manned operation (open - close)
Page 30
R-CRX 2.0 ELECTRONIC CONTROL PANEL FUNCTIONS R-CRX 2.0 230/50-60Hz cod. ABJ8042 • adjustable or infinite operating time • pulsed or dead man operations in opens and/or closes. • directional open - close commands • stop command • radio commands - step by step (open - stop - close) or automatic (open - close) •...
Page 31
J-CRX ELECTRONIC CONTROL PANEL FUNCTIONS J-CRX 120V 60Hz - code ABJ7079 Control of 1 JOLLY BIG TWO Control of 2 JOLLY BIG ONE mounted on the same shutter (works only one group of limit switches) Operation with time Automatic closure...
Page 32
VECOR FLAT STRONG BOX - Embedding Box type 502E not included - Up and down button and alarm inserter not included Safety box preventing the access to controlling devices. Supplied as a standard, with electric brake release system and space for 2 modules in embedded box type 502E.
Page 33
FIT SLIM EN12978 - EN13849-2 SAIL PHOTOCELLS for the wall-installation code ACG8032B 102.5 47.5 PAIR OF COLUMNS FOR FIT SLIM code ACG8065 FIT SLIM photocells have synchronism function in AC current and ranges of 20 m. SAIL orange with built-in flashing board code ACG7072 You can fit many photocell couples close together thanks to the optional synchronizing SAIL white with built-in flashing board...
CARACTERÍSTICAS TÉCNICAS / INSTALACIÓN JOLLY BIG CARACTERÍSTICAS TÉCNICAS JOLLY BIG ONE JOLLY BIG TWO Motores eléctricos N° Peso máx. de la puerta Superficie máx. de la puerta Enrollamiento en el final de carrera N. vueltas Par nominal de funcionamiento Par máximo de trabajo Fuerza máxima de elevación de la tierra...
Page 35
CÓMO INSTALAR JOLLY BIG CON ELECTROFRENO IMPORTANTE: Antes de instalar JOLLY BIG, controle que la puerta enrollable esté correctamente equilibrada con los muelles montados en la barra de arrastre. Verifíquelo manualmente, abriendo y cerrando la puerta enrollable. Ojal Ø 12 mm (entrada del cable de desbloqueo) Hoyo Ø...
CONEXIONES ELÉCTRICAS Esta instrucción es válida sólo si el operador se coloca en el palo en el cierre metálico con el motor dirigido hacia la derecha (visto desde el interno del edificio). CUIDADO: Si el operador viene montado dirigido hacia la izquierda (visto desde el interno del edificio), los movimientos del operador y los del final de carrera se invierten.
Page 37
Conectar el cable de alimentación a los respectivos bornes. CUIDADO: Realizar las conexiones como en el esquema de abajo (pulsador ABRE con el borne OPEN, pulsador CIERRA con el borne CLOSE y al borne COM conectar la fase directa de la alimentación.
Page 38
REGULACIÓN DEL FINAL DE CARRERA AUTOMÁTICO (PATENTADO) A - Cerrar el cierre metálico manualmente. B - Controlar que el interruptor esté en INS. C - Asegurarse de que la excéntrica C1 esté apoyada en el seeger S1 y si no es así, mover la palanca de la excéntrica C1 y girar la excéntrica contra el seeger S1.
Para las conexiones y datos técnicos de los accesorios, consultar los manuales respectivos. CUADROS ELECTRÓNICOS TABLA DE CUADRO ELECTRÓNICO MINI MINI - cód. ABQM090 Gestión 1 JOLLY BIG ONE Funcionamiento con hombre presente (ABRIR - CERRAR) ACCESORIOS ACOPLAMIENTABLES Botonera FLAT...
TABLA DE CUADRO ELECTRÓNICO R-CRX 2.0 R-CRX 2.0 230/50-60Hz cod. ABJ8042 • tiempo de trabajo ajustable o infinito • funcionamiento por impulsos o hombre muerto en abre y/o cierra. • mandos direccionales abre y cierra • mando de stop • mandos radio - paso a paso (abre - para - cierra) o automático (abre - cierra) •...
TABLA DE CUADRO ELECTRÓNICO J-CRX J-CRX 230/50-60Hz - cód. ABJ7080 Gestión 1 JOLLY BIG TWO Gestión 2 JOLLY BIG ONE montados en la misma puerta (funcióna un sólo grupo de fin de carrera) Funcionamiento por tiempo Cierre automático Funcionamiento paso a paso o automático Exclusión cierre automático tota...
Page 42
CAJA FUERTE VECOR FLAT - Caja empotrable tipo 502E no es incluida - El botón arriba y abajo y el inseridor de l’alarma no son incluidos Contenedor de seguridad para impedir el acceso a los dispositivos de mando. Se suministra de serie completa con desbloqueo freno eléctrico y espacio para 2 módulos en caja empotrada 502E.
Page 43
SAIL FIT SLIM EN12978 - EN13849-2 102.5 47.5 FOTOCÉLULAS PARA PARED cód. ACG8032B PAR DE COLUMNAS PARA FIT SLIM cód. ACG8065 SAIL naranja con tablero intermitente incorporado cód. ACG7072 Las fotocélulas FIT SLIM tienen una funciòn de sincronizaciòn en corriente alterna y portada SAIL blanco con tablero intermitente incorporado cód.
Page 45
ITALIANO RAEE - Informazione agli utilizzatori Il simbolo del cassonetto barrato riportato sull’apparecchiatura o sulla sua confezione indica che il prodotto alla fine della propria vita utile deve essere raccolto separatamente dagli altri rifiuti. L’utente dovrà, pertanto, conferire l’apparecchiatura giunta a fine vita agli idonei centri comunali di raccolta differenziata dei rifiuti elettrotecnici ed elettronici. In alternativa alla gestione autonoma, è...
Page 46
REGISTRO DI MANUTENZIONE - DOSSIER D’ENTRETIEN MAINTENANCE LOG - REGISTRO DE MANTENIMIENTO Il presente registro di manutenzione contiene i riferimenti tecnici e le registrazioni delle attività di installazione, Ce dossier d’entretien contient les références techniques et les enregistrements des opérations d’installation, d’entretien, manutenzione, riparazione e modifica svolte, e dovrà...
Page 48
Declaración de incorporación de una cuasi máquina - Directiva de Máquinas 2006/42/CE, Anexo II, B R.I.B. S.r.l. - Via Matteotti, 162 - 25014 Castenedolo - Brescia - Italy Tel. ++39.030.2135811 - www.ribind.it - ribind@ribind.it Apparecchio modello : Oggetto della dichiarazione : Modèle d'appareil :...