2 beeps are emitted to confirm the new code.
4. Check the new user code to be sure
of the modification.
H. SETTING A SUB MASTER CODE
The Sub Master code allows the user to change its
own code without entering in programming mode.
For security reasons the code need to be changed
periodically. This feature makes it easier
and faster to change its code.
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to confirm entry
in programming mode.
2. Press A7 to program a sub master
code for the user individual Pin code
modification.
One beep is emitted. Enter the new 2-digit sub
master code. One beep is emitted to confirm
programming of the sub master code.
3. Press B to exit from the programming
mode.
2 beeps are emitted to confirm that the keypad
is in stand-by operating mode.
I. Audible Feedback
The audible signal is enabled in programming mode
and when the relay is energised after a valid code.
To enable the audible feedback on a key press:
1. Enter the master code twice (1 2 3 4 5
default value master code).
2 beeps are emitted to confirm entry
in programming mode.
2. Press AA.
One beep is emitted. Press 0 to disable the audible
signal during a keypress. Press 1 to enable the au-
dible signal during a keypress. One beep confirms
the new setting.
3. Press B to exit from programming.
2 beeps are emitted to confirm exit
from programming mode.
8
cdvigroup.com
J. OPTIONAL GALEO 2 AND GALEO 3
PROGRAMMING INSTRUCTION
Programming instructions are the same
as for the GALEO keypad with 1 relay output.
GALEO 2: 2 relay outputs N/O and N/C contacts
8A @ 250V~.
---------------------------------------------------------
Group 1: From user location 00
to user location 59 to activate relay 1.
Group 2: from user location 60
to user location 99 to activate relay 2
Release Time of relay2 enter A2, sub master code
enter A8 (default values 1 and 3).
GALEO 3: 3 relay outputs N/O
and N/C contacts 8A @ 250V~.
---------------------------------------------------------
Group 1: from user location 00
to user location 59 to activate relay 1.
Group 2: from user location 60
to user location 79 to activate relay 2.
Group 3: from user location 80
to user location 99 to activate relay 3.
Release time for relay 3 enter A3
sub master code enter A9 (default values 4 and 6).