4. Technical Data

Voltage:
Power consumption:
Double insulation:
Heat Output
Power cable:
Weight:

5. Description

1) ON/OFF switch:
0 = OFF
I = ON Stage I (230°C)
I = ON Stage II (360°C)
2) Grip surfaces
3) Fold-out pedestal
4) Ventilation openings
5) Metal nozzle
Depending on the type of application, the F100 can be held / used in
i
various ways.
Danger of burns from hot nozzle and air. Only hold the heat gun at the
grip surfaces and always wear heat-resistant work gloves. Do not block
the ventilation openings.
a) Gun grip:
for larger applications
Technical Data
220-240 V ~ , 50-60 Hz
170 W (stage I), 350 W (stage II)
approx. 230°C (stage I), approx. 360°C (stage II)
1.8 m
0.33 kg
2
4
b) Pencil grip:
for smaller applications
where precision is
needed.
1
3
2
c) Setup with pedestal:
for free-handed working
and for cooling the heat
gun
GB
5
13