Installation
Mains
220-240 V~ 50/60 Hz
200-240 V~ 50/60 Hz
Use only ul listed or csa approved components
3.5 Connection of the cooktop
3 Phases:
Use the brass bridges which are in the connection
box to bridge terminals 1-2 and terminals 4-5.
Connect line 1 to the terminal 1, line 2 to the termi-
nal 3, line 3 to the terminal 5 and the
ground to terminal
2 Phases:
Use the brass bridges which are in the connection
box to bridge terminals 1-2-3 and terminals 4-5.
Connect line 1 to the terminal 1, line 2 to the
terminal 5 and the ground to terminal
A
Caution! Ensure that the cables
are correctly inserted and tightly
screwed down.
We cannot be held responsible for
any incident resulting from incor-
C
rect connection or which could arise
from the use of an appliance which
has not been earthed or has been
equipped with a faulty earth con-
nection.
12 / EN
Connection
Cable diameter
3 Phases
4 x 8 AWG
2 Phases
3 x 8 AWG
Protection calibre
50 A
55A
3.6 Position of nameplate
The nameplate is located under the cooktop, as
shown on the picture below. When ordering parts
for or making inquiries about your cooktop, always
be sure to include the model and serial numbers
and a lot number or letter from the serial plate on
your cooktop.
Nameplate label
Induction Hob / User Manual
Flexible conduit
¾"
¾"