ussc run 1 emissions
– Volume of Gas Sampled Corrected to Dry Standard Conditions, dscf
V
m(std)
ASTM E2515 equation (6)
Where:
17.64 °R/in. Hg
K
=
1
V
=
Volume of gas sample measured at the dry gas meter, dcf
m
Y
=
Dry gas meter calibration factor, dimensionless
P
=
Barometric pressure at the testing site, in. Hg
bar
∆H
Average pressure differential across the orifice meter, in. H
=
Absolute average dry gas meter temperature, °R
T
=
m
Sample Calculation:
Using equation for Train A:
V
=
17.64
x 53.507 x
m(std)
50.912
V
=
dscf
m(std)
Using equation for Train B:
V
=
17.64
x 52.946 x
m(std)
V
=
50.294
dscf
m(std)
Using equation for ambient train:
V
=
17.64
x
m(std)
V
=
0.000
dscf
m(std)
PFS-TECO
(
0.999
x
(
(
0.996
x
(
(
0.00
x
0.992
x
(
O
2
2.19
29.99 +
)
13.6
98.3 +
460
)
2.17
29.99 +
)
13.6
97.6 +
460
)
0.00
29.99
+
)
13.6
77.0 +
460
)
Page 8 of 14