Extended Menu - Comunello Automation BORDER 400 Instructions D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

SLOWING menù with LED L7 off); if you wish to change the profile to a
medium level value "MED" proceed as follows: use the SEL key to select
blinking LED L7 and press the SET key; at the same time LED L7 becomes
steady on and programming will be completed. If you wish to change the
profile to a Minimum value "MIN" repeat the operation described above,
pressing the SEL key twice (LED L7 will blink rapidly) rather than once.
Repeat the procedure if you wish to restore the initial configuration.

EXTENDED MENU 1

The control unit is factory set to allow direct selection exclusively of the main
menu functions.
If you wish to enable the functions described in Extended Menu 1, proceed
as follows: select blinking LED LEV and press SET 1 times. The LED will
start blinking alternately 1 0 1 0 1 0. This means you have 30 seconds to
select the functions of Extended Menu 1 using the SEL and SET keys; once
an additional 30 seconds have elapsed, the control unit reverts to the main
menu.
L1
REMOTE PROGRAMMING
L2
DIR
L3
AUTO PROGRAM
L4
FOTO TEST
L5
SAFE 1 IN OPEN
L6
DO NOT USE
L7
DO NOT USE
LEV
MENU
1. REMOTE RADIO CONTROL PROGRAMMING:
The control unit allows the transmission code to be programmed remotely
without acting directly on the control unit SEL key.
Remote programming of a Radio remote control is performed as follows:
send the code of a previously saved remote continuously for more than 10
seconds; at the same time the control unit switches to programming mode
as described above for LED L1 in the main menu. If you wish to enable
the remote programming function, proceed as follows: ensure you have
enabled Extended Menu 1 (alternate blinking 1 0 1 0 1 0 of menu level
no. 8) and then use the SEL key to select blinking LED L1 and press the
SET key; LED L1 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the initial configuration.
2. OPENING DIRECTION (DIR):
In the default configuration the control unit is set with "BEAM AT LEFT"
logic (Fig. 10B); if the "BEAM AT RIGHT" logic must be enabled (Fig. 10A),
proceed as follows: use the SELECT key to select the blinking DIR LED
and press the SET key: the OPEN DIRECTION LED will light steady and
programming will be completed. Repeat the procedure if you wish to
restore the previous configuration.
3. AUTOMATIC PROGRAMMING:
The control units allows to make an Automatic Programming (SIMPLIFIED)
in the following way: be sure of having positioned the Barrier open at 45°
and of having enabled the Extended Menu 1 (pointed out by flashing 1
0 1 0 1 of the 8th led), use the SEL key to select the 3rd blinking LED:
pressing continuously SET key, the control unit executes the Auto
Programming procedure by performing a complete opening and closing
cycle (keep the SET key pressed until Auto Programming is finished). During
the programming procedure, the Deceleration cycle is automatically set at
approximately the 15% of the complete cycle.
During the Automatic Programming it is possible to use the button of
the remote control instead of the SET key of the control unit, but only
if previously memorized.
4. FOTOTEST (Photocells test):
The control unit is factory set with the photocells test disabled. If you wish
to enable the photocells test proceed as follows: ensure you have enabled
Extended Menu 1 (blinking 1 0 1 0 1 of LED LEV) and then use the SEL key
to select blinking LED L4 and press the SET key; LED L4 becomes steady
on and the operation will be completed. Repeat the procedure if you wish to
restore the previous configuration.
5. SAFE 1 also in opening:
The control unit allows the operation of input DS1 to be modified. If you want
SAFE 1 to operate also during opening (momentary stopping of the barrier,
as soon as the photocell is freed the control unit resumes the opening
LED OFF
LED ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
1 FLASH
movement), proceed as follows: ensure you have enabled Extended Menu
2 and then press the SEL key to select blinking LED L3 and press the SET
key: LED L3 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the initial configuration.
6. NOT USED
7. NOT USED
EXTENDED MENU 2
The control unit is supplied by the manufacturer with the facility for direct
selection only from the main menu functions. If you want to enable the
functions described in Extended Menu 2, proceed as follows: select blinking
LED LEV and then press SET twice. The LED will start blinking alternately
1 1 0 1 1 0. This means you have 30 seconds to select the functions of
Extended Menu 2 using the SEL and SET keys; once an additional 30
seconds have elapsed, the control unit reverts to the main menu.
L1
DO NOT USE
L2
FLASH.OUT.CNTRL.
FLASHING LIGHT
L3
ALWAYS CLOSE
L4
FOLLOW ME
L5
PRE-FLASH
L6
DO NOT USE
L7
DO NOT USE
LEV
MENU
1. NOT USED
2. 24V 4W MAX FLASHING LIGHT OUTPUT CONTROL:
The control unit is factory set with an intermittent output for connection
to a 24V Flashing light (0.5 sec ON – 0.5 sec OFF). If you wish to enable
a fixed output, proceed as follows: ensure you have enabled Extended
Menu 2 (blinking 1 1 0 1 1 0 1 0 of LED LEV) and then use the SEL key to
select blinking LED L2 and press the SET key; LED L2 becomes steady on
and programming will be completed. Repeat the procedure if you wish to
restore the previous configuration.
3. ALWAYS CLOSE:
The control unit provides the facility to set "Always Close" operation: this
function, which is programmable only if a Pause Time has already been
programmed, is activated after a power loss; if the barrier open condition
is detected, a closing movement will be started automatically, preceded
by 5 seconds of preflashing. If you wish to exclude this operating mode
proceed as follows: ensure you have enabled Extended Menu 2 (blinking
1 1 0 1 1 0 of LED LEV) and then use the SEL key to select blinking LED
L3 and press the SET key; LED L3 becomes steady on and the operation
will be completed. Repeat the procedure if you wish to restore the previous
configuration.
4. FOLLOW ME:
The control unit allows the "Follow me" function to be configured;
programmable only if a Pause Time has already been set, this function
reduces the Pause Time to 5 seconds after freeing the DS1 photocell,
meaning the barrier re-closes 5 seconds after transit of the user.
If you wish to enable this function proceed as follows: ensure you have
enabled Extended Menu 2 (blinking 1 1 0 1 1 0 of LED LEV) and then
use the SEL key to select blinking LED L4 and press the SET key; LED
L4 becomes steady on and programming will be completed. Repeat the
procedure if you wish to restore the previous configuration.
5. PREFLASHING:
The control unit is factory set with the Preflashing function disabled. If you
wish to enable the Preflashing function, proceed as follows: ensure you have
enabled Extended Menu 2 (blinking 1 1 0 1 1 0 1 0 of LED LEV) and then
use the SEL key to select blinking LED L5 and press the SET key; LED L5
becomes steady on and programming will be completed; in this manner the
flashing light output will always switch on 3 seconds before the barrier starts
moving. Repeat the procedure if you wish to restore the initial configuration.
6. NOT USED
7. NOT USED
COMUNELLO ®Copyright 2015 - All right reserved
LED OFF
LED ON
DO NOT USE
DO NOT USE
PERMANENT
OFF
ON
OFF
ON
OFF
ON
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
2 FLASHES
23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Border 600

Table des Matières