INSTALLATION OF THE PANEL HEATER
Please read the instructions before starting to install the heater. Disconnect
the power before carrying out any work on the heater. Keep these
instructions even once you have installed your heater.
1) Where to install your heater ?
- This equipment was designed to be installed in a residence. Please ask your
distributor before using it for any other purpose.
- The panel heater should be installed according to normal trade practice
and in compliance with legislation in the relevant country (the IEE Wiring
Regulations).
- The equipment is class 2 and is protected against splashed water. The
device is to be installed so that switches and other controls cannot be
touched by a person in the bath or shower, except in the UK where IEE
Regulations 701.512.2 and 701.512.3 apply. These allow the use of IP24
rated products and their integral controls in Zone 2 and outside zones.
- Comply with the minimum clearance distances for positioning of the panel
2
heater.
- If your wall covering is laid on foam, a spacer the same thickness as the
foam must be placed under the panel heater's support. This ensures there
is free space behind the panel heater to make sure its control settings are
not adversely affected.
- Do not install the panel heater:
In a draught that might affect adjustment (for example, under a
central mechanical ventilation unit etc...).
Under a fi xed mains power socket.
1
In zone 1 of bathrooms.
It is forbiden to install vertical product in horizontal position.
2) How to install the panel heater ?
2-1) Release the appliance's hook-on bracket
We recommend that you place the radiant panel flat, face down.
Have a straight head screwdriver to hand.
2-2) Fix the hook-on bracket
Use the wall-mounting bracket as a template for positioning the heater.
Drilling points A
Drilling points B
Note : Do not use the device in mobile or feets or on casters. (diagram
2-3) Connecting the panel heater
- The appliance should have a 230-240V 50Hz power supply.
- The panel heater must be connected to the mains, either by a 2-wire cable
(Brown = Phase, Blue = Neutral) via a power socket (Product with plug :
diagram
A) or connexion box (Mechanical thermostat : diagram B) ; by a
3-wire cable (Brown = Phase, Blue = Neutral, Black = Pilot wire) by means
of a connexion box (version with pilote wire : diagram C).
In humid areas such as bathrooms and kitchens the power socket must be
installed at least 25 cm above the floor.
- The installation should be fi tted with a double pole break device with a
break of at least 3 mm.
- Connection to earth is prohibited. Do not connect the pilot wire
(black) to earth.
- The heater must be installed by a qualified electrician in accordance with
the local regulations. The heater and the pilot wire (black) must NOT be
connected to earth. If the power cable is damaged, it must be replaced by
the manufacturer or its after-sales service Department or a similary qualifi ed
person to avoid any risk.
If a pilot or piloted panel heater is protected by 30mA differential (e.g.
bathroom) the pilot wire's power must be protected on this differential.
Commands
No current
received
Oscilloscopes
Réf/Neutral
Mode
COMFORT
obtained
Complete
Négative
alternation
half-alternation
230 V
- 115 V
ECO
ANTI-FREEZE
1
2-4) Lock the appliance on the hook-on bracket
1) Description of the control unit : 7 8 9
/I /
knob.
V1
2) Fixing the comfort temperature
The comfort temperature is the temperature that you would like while the
room is occupied.
a) Put the
b) Mechanical : set the
Electronical : ajust the control knob
indicator V1 comes on if the room temperature is below the required
temperature.
c) Wait a few hours for the temperature to stabilise.
d) If the setting is satisfactory (if necessary use a thermometer to check),
mark the position for future use.
e) If the setting is not satisfactory, adjust it and start again from point c).
C)
3) Fixing the Eco temperature :
This is the required temperature during periods when the room is
unoccupied. It is recommended that this mode should be used if the room is
unoccupied for more than 2 hours.
a) Set the cursor
b) Ajust the control knob
comes on, if the ambient temperature is lower than the instruction of desired
Eco temperature.
c) Wait a few hours until the temperature stabilizes.
d) If the setting is satisfactory (if necessary use a thermometer to check),
mark the position.
If the setting is not satisfactory, adjust it and start again from point c.
4) Frost-Free mode
This mode is used to keep the temperature at approximately 7°C in the
room when you are absent from the house for a prolonged period (i.e. more
than 24 hours).
a) Leave the
b) Set the
5) The heating indicator : V1 (electronic model)
Positive
half-
This light comes on when the heating element is working. It may flash when
alternation
the temperature has stabilised.
+ 115 V
6) Locking the controls :
It is possible to lock or limit use of the
to prevent unauthorised manipulation of the panel heater (children, etc.).
STOP
a) Unhook the panel heater from its wall mounting.
HEATING
b) Remove the slugs P on the back of the thermostat from their mountings.
– LOAD
c) Select position B to lock the control knob or position L to limit the amount it
SHEDDING
can be turned. Position M blocks the switch for Electronic Model.
USING THE PANEL HEATER
switch (stop/0).
Temperature adjustment control
Heating indicator light
switch to
(marche/I).
control knob to between 4 and 5.
to the wished position, the heating
switch knob to .
to the wished position, the heating light V1
switch on I , set the
control knob to
switch on
(electronic model).
and
control knob and lock the
B
C
(electronic model)
(mecanical model).
11
switch