WIKA TW61 Mode D'emploi page 9

Masquer les pouces Voir aussi pour TW61:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. Design and function
For model TR22-B resistance thermometer
2) In the event of replacement, select a resistance thermometer measuring insert model TR11-A.
The corresponding sensor length, l
Insertion length U
+ neck tube length M (85 mm) + 5 mm pre-load + 10 mm head dimension
1
DIN 11866 series A or metric
Nominal
Nominal
width of
pressure
tube
in bar
OD
PN
3) 4)
10
25
15
25
20
25
25
25
32
25
25
40
50
25
65
16
80
16
100
12.5
3) Maximum operating temperature 150 °C
4) All thermowells of this model series which are exposed to internal pressure and have a nominal diameter (DN) of
> 25 mm are manufactured and tested in accordance with module H of the pressure equipment directive.
WIKA operating instructions thermowell, model TW61
, is calculated as follows:
5
Outer
Tube wall
diameter
thickness
of pipe
Ø D
s
13
1.5
19
1.5
23
1.5
29
1.5
35
1.5
41
1.5
53
1.5
70
2.0
85
2.0
104
2.0
Tube
Thermowell
length
insertion
length
TL
U
1
70
6
70
9
80
11
100
18
110
18
120
18
160
30
210
30
260
45
310
45
EN
Neck tube
length
TR21-B TR22-B
M
M
51
129
48
126
46
124
39
117
39
117
39
117
27
105
27
105
12
90
12
90
9

Publicité