Wizard
The first time the unit receives the power supply, it will enter into Wizard mode.
The display will show the messageIn{flashing at 0.
The buttons and change the value, the SET button accepts
the value and moves on to the next step.
Step 1:
Select the most suitable InI option based on the type of installation to be
carried out and press SET.
The available options will be shown in the following table:
Type of installation
InI
Control of
Pump
the compressor
Down
Demo mode: it displays the temperature but does not regulate the temperature
0
No
No
1
Yes
Yes
2
Yes
No
3
No
No
4
Yes
Yes
5
Yes
No
6
Yes
Yes
7
Yes
No
8
* If u00=2: o20=3, I30=0, I31=0
If u00≠2: o20=0, I30=9
If options 2, 5 or 7 are chosen, check the configuration of parameter I11 according to the pressure switch
type used.
Step 2:
Choose the type of expansion valve to be used:
Liquid solenoid valve +
u00=0
thermostatic expansion valve
u00=1
PWM-controlled solenoid valve
Electronic expansion valve (requires an external controller for
u00=2
the EEV. For more information, please refer to the
note
available on our website)
If u00=0 is chosen, steps 4, 5, 6, 7, 8, 9 and 11 are not displayed.
If u00=2 is chosen, step 3 is not displayed.
Evap.
Defrost
Pd o00 o20 I00 I10 I11 I20 I21 I30 I31 d1 D7 F3
Fans
Consumption
Yes
0
Consumption
Yes
1
Consumption
Yes
0
Air
Yes
0
Air
Yes
1
Air
Yes
0
Hot gas
Yes
1
Hot gas
Yes
0
21
1
2
Parameters
3
0
*
2
0
0
0
1
*
2
7
1
0
1
*
2
0
0
0
0
*
1
0
0
0
1
*
1
7
1
0
4
1
*
1
0
0
0
1
*
2
7
1
7
1
*
2
0
0
7
1
5
2
6
3
application
7
4
8
351652611 Ed. 02
/ / SET
/ / SET
0
*
* 20 0
0
0
*
* 20 0
0
0
*
* 20 0
0
0
*
* 20 1
1
/ / SET
0
*
* 20 1
1
0
*
* 20 1
1
1
*
*
5
2
0
1
*
*
5
2
0
/ / SET
/ / SET
/ / SET
/ / SET
/ / SET
/ / SET
/ / SET