Ingersoll Rand CCE10 Manuel De Maintenance page 13

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATION (CONT'D)
Initial Start Up
1. Inspect unit for any visible signs of damage that would have occurred in shipment or during
installation.
2. Pull main disconnect switch to unit to assure that no power is coming into the unit. "Lock Out" or "Tag
Out" switch. Connect power leads to starter.
Do not attempt to operate compressor on voltage other than that specified on order
or on compressor motor.
3.
Activate main disconnect switch.
4.
"Jog" motor and check for proper rotation by direction arrow. If rotation is wrong, reverse input
connections on the magnetic starter.
5.
Close receiver outlet hand valve and start.
6.
With receiver hand valve closed, let machine pump up to operating pressure. At this stage the
automatic controls will take over. Check for proper cycling operation.
7.
Check for proper operation of any options. Refer to individual option instruction sheet.
8.
Open receiver hand valve. The air compressor unit is now ready for use.
This unit can start automatically without warning.
IF3266 Rev A Page 13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cce30Cve50

Table des Matières