ENGLISH
Charcoal filter maintenance (if the hood is
installed in recirculation mode)
1. Unplug the appliance or disconnect the
power supply.
2. Remove the grease filter
3. If charcoal filters are already present
(two filters fitted, covering the protection
grids of the motor impeller) and must
be replaced, turn the central handle
anticlockwise to unlock them. Reverse
procedure to install new ones.
4. Refit the grease filter.
Charcoal filter is neither lavable nor
regenerable.
Replace the charcoal filter every 4
months.
Replacing the Halogen lamps
WARNING: - Only use 10W MAX - G4
halogen lamps.
1. Disconnect the hood from the electric
power supply.
2. Insert the blade of a small flat
screwdriver where indicated by the
three points, and with a gentlepressure
remove the light cover from its position.
3. Remove the faulty lamp and replace
with a new one.
4. Replace the cover (spring lock system).
IMPORTANT: make sure you don't touch the
lamp with your hands.