5. Press OK to confirm. The hour
indicator is blinking.
6. Press
or
7. Press OK to confirm. The minute
indicator is blinking.
8. Press
or
minutes.
9. Press OK to confirm. The text says
SAVED for 2 seconds. The menu is
automatically closed.
2.9 Setting the COMF
(Comfort temperature)
The
ventilation
comfortable an air-temperature supply
as possible on the basis of a set comfort
temperature.
It is best to set the comfort
temperature to the same
temperature as the room
thermostat (of the central
heating system).
1. Press OK. The text says SHIFT for 8
seconds.
2. Press MENU before the text SHIFT
disappears. The text says COMF.
3. Press OK to confirm. The current set
temperature is blinking.
4. Press
or
comfort temperature.
5. Press OK to confirm. The text says
SAVED for 2 seconds. The menu is
automatically closed.

2.10 Switching the FAN

When wanted, the supply (IN) or exhaust
(OUT) fan of the ventilation unit can be
turned off manually. This may be desired to
keep out unpleasant odors from outside.
Bear in mind that switching off a fan will
to choose the hour.
to choose the
unit
strives
for
to choose the
temporarily immobilize your dwelling's
balanced ventilation system, so do not
forget to turn the fans on again.
When can the FAN not be switched?
To prevent air being sucked back from
the chimney of a fireplace the ventilation
unit is fitted with an open fire program.
When needed the installer or maintenance
mechanic can turn this program on. If
the fire program is turned on the supply
(IN) fan and exhaust (OUT) fan cannot be
turned on or off manually.
When can the supply (IN) fan not be
turned on?
The supply (IN) fan cannot only be
operated manually but can also be
controlled automatically by the ventilation
unit itself. This occurs in the winter to
as
protect the ventilation unit from freezing.
If the supply (IN) air is too cold for the
ventilation unit, the ventilation unit will
switch the supply (IN) fan automatically
off. In this case the supply (IN) fan cannot
be turned on manually.
1. Press OK. The text says SHIFT for 8
seconds.
2. Press MENU before the text SHIFT
disappears. The text says COMF.
3. Press
4. Press OK to confirm. The text says
IN, OFF.
5. Press
to switch on or off. The following
options can be chosen:
■ IN OFF
■ OUT OFF = Switch off the
■ BOTH ON = Switch on both fans.
6. Press OK to confirm. The text says
SAVED for 2 seconds. The menu is
automatically closed. The symbol of
the chosen option is visible.
once. The text says FAN.
or
to choose which fan
= Switch off the supply
fan;
exhaust fan;
EN - 23