Code
Condition
d0
IPM mould temperature
d1
Inlet water temp.
d2
Outlet water temp.
d3
Ambient temp.
d4
Frequency limitation code
d5
Piping temp.
d6
Gas exhaust temperature
d7
Step of EEV
d8
Compressor running frequency
d9
Compressor current
d10
Current fan speed
d11
Error code for last time
6.2.2 Temp & COP curve
Click
to check the Temp & COP curve. Only after the heat pump runs 4 minutes under heating mode, COP curve
can be showed;
6.2.3 Parameter setting
There are also four interfaces (Parameter A-D) as below pictures shows. Page up or down same as parameter query.
Scope
0-120℃
-9℃~99℃
-9℃~99℃
-30℃~70℃
0,1,2,4,8,16
-30℃~70℃
0℃~C5℃ (125℃)
0~99
0~99Hz
0~30A
0-1200 (rpm)
All error code
17
Remark
Real testing value
Real testing value
Real testing value
Real testing value
Real testing value
Real testing value
Real testing value
N*5
Real testing value
Real testing value
Real testing value