LoRaWAN AS-923 Pulse - Guide utilisateur / User guide version V1.0.0
0
Code
Status
0x48
Cf Status
0x48
0xA3
0
Code
Status
0x48
Cf Status
0x48
0xA3
4.1.10
Summary of the conditions of the transmission of the uplink frames
The table below summarizes the conditions of the transmission of the different uplink frames:
Code
Description
0x10,
Product configuration data frames
0x11,
0x12
0x20
Frames of information on the
network configuration
0x30
Keep Alive frame
0x31
Reply frame to a register value
request
0x46
Data Frame
0x47
Alarm frame
0x48 (x4) Periodic frame with 1 hour-history
0x48
Periodic frame with 24 hours-
(x13)
history
1
2
Frame index
11
1
2
Frame index
12
• Start-up of the product
• Exit from the configuration mode
• Reception of a downlink frame 0x01
• Periodically if the inputs are deactivated (period defined by register S301)
• Start-up of the product
• Exit from the configuration mode
• Reception of a downlink frame 0x02
24 hours elapse since the start-up of the product or since the last transmission of this frame
(5 minutes in TEST mode)
• Reception of a downlink frame 0x40
•
Start-up of the product (RUN mode).
•
Exit from the configuration mode (AT commande)
•
Transmission period reached (period defined by register S301)
Exceeded flow threshold on one of the two channels (sending only if the exceeded flow
control is enabled by writing a non-zero value in the S326 or S327 registers).
1 hour elapses since the start-up of the product or since the last transmission of this frame
This frame is sent only if the history feature is activated in register S321.
24 hours elapse since the start-up of the product or since the last transmission of this frame
This frame is sent only if the history feature is activated in register S321.
3 to 4
5 to 6
PAYLOAD
Delta A20
Delta B20
0x00C3
0x00F1
3 to 4
5 to 6
PAYLOAD
Delta A22
Delta B22
0x0012
0x0020
Sending conditions
7 to 8
9 to 10
Delta A21
Delta B21
0x0005
0x00B5