3.3.1 Registres fonction
The list of registers below allows you to change the behaviour of the product application.
Register
Size
(bytes)
FR
300
N/A
301
2
EN
303
1
304
2
306
1
320
1
Description
Transmission period of the
Keep Alive frame
Transmission period of data
sensors
Confrmed mode activation
PIN code
Global operation
Channels configuration (A
and B)
Coding
Details
Ignored value, the period is set to 24 hours (not configurable)
---
in OPERATION mode and 5 minutes in TEST mode
Decimal
Default value: 1440
Min/max : 1 to 1440
Unit:
x 1min if S306=1
x 20s if S306=2
Decimal
Default value : 0 (desactivated)
Values : 0 (desactivated) to 1 (activated)
Decimal
Default value : 0 (disabled)
Min/max : 0 to 9999
PIN code used with ATPIN command.
Value 0 disables the PIN code.
IMPORTANT: The product does not have a mechanism
to unlock the PIN code if it is activated and the code
is forgotten.
Decimal
Default value: 0
Allows the product to be switched into one of the following
modes:
• 0: PARK mode
• 1: Production mode
• 2: TEST mode
• 3: DEAD mode
Hexadeci-
Default value: 0x11
mal
For channel A :
•
Bit 0 : channel A activation
• Value 0: channel deactivated
• Value 1: channel activated
•
Bit 1 : meter type channel A (pull-up activation)
• Value 0: meter other than Gas (pull-up deactivated)
• Value 1: Gas meter (pull-up activated)
•
Bit 2 : Reserved
•
Bit 3 : tamper input channel A
• Value 0: deactivated
• Value 1: activated
For channel B :
•
Bit 0 : channel B activation
• Value 0: channel deactivated
• Value 1: channel activated
•
Bit 1 : meter type channel B (pull-up activation)
• Value 0: meter other than Gas (pull-up deactivated)
• Value 1: Gas meter (pull-up activated)
•
Bit 2 : Reserved
•
Bit 3 : tamper input channel B
• Value 0: deactivated
• Value 1: activated
Page
72