2. Install screws (or other hardware appropriate for the mounting
surface) through the two mounting holes near the top of the
enclosure. Install the last screw through the mounting hole near
the bottom of the enclosure. Mounting hardware must be driven
until the head fully contacts the enclosure wall. Mounting hardware
head must not be smaller than 0.25 inches (6.3 mm) in diameter
and the threads of the hardware must be smaller than 0.25 inches
(6.3 mm) in diameter.
2C. Electrical
2C-1. Main Power
This device is intended to be installed by a certified electrical
technician, in accordance with local electrical codes. Connect the
DEL Eclipse to the pool timing clock so that the DEL Eclipse operates
simultaneously with the pool pump. The DEL Eclipse has three
available Knockouts for a 1/2 inch conduit fitting, two on each side
and one on the back. Remove only the ideal Knockout and install the
proper conduit fitting. Open the Enclosure and locate the Terminal
Block. Connect Line 1, Line 2, and Ground to the Terminal Block as
indicated by the label on the inside of the enclosure door. Refer to the
IMPORTANT SAFETY INSTRUCTIONS at the beginning of this manual
for important wiring information.
2C-2. Earth Grounding Lug
Using an 6 AWG (13.3 mm
on the bottom of the DEL Eclipse, marked to an appropriate earth
contact.
2D. Plumbing
Ozone gas is introduced to the pool circulation line using a venturi
injector. Suction developed by the venturi allows the DEL Eclipse
generator to operate safely under vacuum.
Note: Water must not travel back to the ozone generator. Mounting
the unit above the water line and scheduled check valve replacement
will keep water from entering the DEL Eclipse.
2D-1. Plumbing the Injector Manifold
The Injector Manifold must be installed in the pool's main return line
after all other pool equipment (pump, filter, heater, and cleaner). Figure
2 shows the most basic installation. For installation with additional
oxidizers and pool cleaners, refer to Appendix A.