Broan Elite 61000 Série Mode D'emploi page 8

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CONNECT DUCTWORK
Non-Ducted Configuration
1. Use screws (4.8x38mm) and wall
anchors (supplied) to secure the
upper bracket to wall and ceiling
as shown.
2. Turn upper flue section upside down
so air vents are at the top. Slide
upper flue section into lower flue
section.
3. Snap the plastic duct collar into the
hole in the bottom of the ductfree
plenum. Connect the ductfree
plenum to the upper flue section with
(4) flat-head screws (2.9x13mm).
4. Measure the distance from the top
of the discharge collar to the
ceiling. Cut a length of 6" round
metal duct 5" shorter than this
dimension.
5. Fit duct section over the plastic duct
collar. For best fit, make sure duct seam is toward the front.
6. Set duct/flue assembly on hood with top tilted away from wall. Reach around flue
to engage bottom of duct with discharge collar on hood. Tilt flue up against wall.
Duct seam can be cut to length if necessary.
7. Raise upper flue section and screw it to upper bracket with (2) screws (3.9x9.5mm).
Screw lower flue section to hood with (2) screws (3.9x9.5mm).
DUCTFREE FILTER
INSTALLATION
1. Purchase a ductfree filters (ROUND FILTER
- cod. B03300498) from your dealer.
2. Position the filters over the mounting
brackets on the blower inlet.
3. Rotate to lock filters in place.
UPPER
FLUE SECTION
(in upper flue section)
DUCTFREE
PLENUM
PLASTIC
DUCT COLLAR
DUCT
LOWER
SEAM
FLUE SECTION
6" ROUND
METAL DUCT
DISCHARGE
COLLAR
- 8 -
UPPER
AIR
BRACKET
VENTS
MEASURE
DUCTFREE
FILTERS

Publicité

Table des Matières
loading

Table des Matières