BRUSH INDICATOR

The brush indicator
will spin (E) when the
cleaner is turned on
and the brushes are
rotating. If the indicator
does not spin (F) and the pattern is visible
when the cleaner is turned on, the brushes
are not rotating. (See Figure 15)
There are two reasons the brushes may not be rotating:
1.
Brush speed selector is turned to Spill Pick Up
(see previous section)
2. Brush indicator screen is dirty
CLEANING INDICATOR SCREEN
WARNING! To reduce the risk
of electric shock, unplug
before cleaning or servicing.
1.
Remove clear cover and wipe off
screen (G) with a damp cloth.
2. Snap cover back into position.
(See Figure 16)
TANKS

CLEAN SOLUTION TANk

The clean solution tank holds the cleaning solution that
is dispersed onto the surface to be cleaned.
WARNING! To reduce the risk of electric shock,
unplug before cleaning or servicing.
Figure 17
1.
Place cleaner handle in the upright, locked position.
To remove tank, press down on handle and pull
forward. (See Figure 17)
2. Carry tank to a sink. Rotate tank cap counter-
clockwise and lift up to remove. (See Figure 18)
3. Turn cap (H) upside down to serve as a measuring
cup. (See Figure 19)
PAGE 4 OF 14
INSTrUCTIONS CONTINUED
E
F
Figure 16
Figure 18
Figure 19
I
H
Using cap, measure detergent as follows:
1.
Fill cap with 3 oz HOOVER 2X Carpet/Upholstery
Detergent.
2. Do not use any type of wax with your SteamVac
cleaner. To assure proper performance, it is
recommended that only HOOVER detergent be
Figure 15
used. It is specifically formulated for use with the
cleaner.
WArNING! Detergents contain Anionic and
Nonionic Surfactants. Avoid contact with eyes
and skin. In case of contact with eyes, flush
with cold water for 15 minutes. In case of
contact with skin, wash with water. If irritation
persists, call a physician. For medical
information (U.S.) call 1-800-752-7869.
G
3. Pour detergent into tank. Fill tank to fill line (J)
(1 gallon) with hot tap water. (See Figure 20)
4. If rubber ring (k) on cap has displaced, replace
it with uneven side against cap ledge (L) as shown.
(See Figure 21)
5. Replace cap. Rotate cap clockwise until it locks
in place. Cap must be locked in place for proper
performance and to prevent leaking.
(See Figure 22)
6. Position bottom of tank into unit and press on tank
handle to snap tank into place. (See Figure 23)
Figure 21
Figure 20
J
Figure 23
Figure 22
K
L
0713 IH-3482