Requirement # 1 : The code requires that the chimney must extend at least 3 feet above the highest point of the roof that it penetrates.
Requirement # 2 : The chimney must also be 2 feet above any roof, wall or other obstruction within a horizontal distance of 10 feet.
The following Chart is to assist you in determining the minimum chimney height you will require above the roof. You may need to add to this height as nearby
buildings, trees and other parts of the house roof could interfere with airflow over and around the top of the chimney and affect its performance. If you think
a nearby obstacle could affect draft, you might want to install one or more additional lengths.
DISTANCE
FROM PEAK
10 Ft
9 Ft
8 Ft
7 Ft
6 Ft
5 Ft
4 Ft
3 Ft
2 Ft
1 Ft
• If the chimney extends 5 feet or more above the roof, a Universal Roof Guy Kit (JURGK-1) is required.
• It is highly recommended that any lengths above the roof should have locking bands at all joints for added safety and stability. This will eliminate the risk of
sections becoming undone below the roof line when the Rain Cap is removed when inspections and cleaning of the system is being done.
CHART 3 - Connector Pipe Clearance below Cathedral Support
1. Identify the type of connector pipe you will be installing, single wall (requires 18" clearance to combustibles) or Selkirk's Double Wall Stove Pipe (model DSP)
which requires 6" clearance to combustibles.
2. Determine the amount of the exposed Cathedral Support that will be projecting into the room as per the "X" in the diagram on the bottom left.
3. Select the pitch of your sloped ceiling from the chart below.
4. Select the measurement from the chart below where the pitch of the sloped ceiling column intersects with the exposed Cathedral Suppport row selection. This
will determine the measurement of insulated chimney required below the Cathedral Support as per the "Y" in the diagram on the left. The minimum of insulated
chimney below the Cathedral Support is 1 inch. This minimum is required for stability of the system.
Cathedral
Support
Y
Chimney Length
1
Single Wall Flue Pipe requires 18" clearance from any combustible materials.
2
DSP Double Wall Stove Pipe requires 6" clearance from any combustible materials.

CHART 2 - CHIMNEY HEIGHT ABOVE THE ROOF

2/12
3/12
1/12
*36
44
54
42
51
*36
40
48
*36
*36
38
45
*36
36
42
*36
39
*36
*36
*36
36
*36
*36
*36
*36
*36
*36
*36
*36
*36
* Defaulted to 36" to meet requirement #1. Both requirements (#1 and #2) must be met.
CONNECTOR PIPE CLEARANCE REQUIREMENTS FROM SLOPED CEILING
EXPOSED
CATHEDRAL SUPPORT
INTO ROOM
"X" measurement
Box flush to ceiling on
lower end
Box 1" into the room
Box 2" into the room
Box 3" into the room
X
"X" measurement
Insulated
Box flush to ceiling on
lower end
Box 1" into the room
Stove Pipe
Box 2" into the room
Adaptor
Box 3" into the room
PITCH OF ROOF
4/12
5/12
6/12
7/12
CHIMNEY HEIGHT ABOVE ROOF (INCHES)
64
74
84
60
69
78
56
64
72
52
59
66
48
54
60
44
49
54
40
44
48
36
39
42
*36
*36
36
*36
*36
*36
*36
1/12
2/12
3/12
"Y" MEASUREMENT - INSULATED CHIMNEY LENGTH INTO ROOM
1.5
3
4.5
1
2
3.5
1
1
2.5
1
1
1.5
"Y" MEASUREMENT - INSULATED CHIMNEY LENGTH INTO ROOM
1
1
1.5
1
1
1
1
1
1
1
1
1
23
9/12
8/12
10/12
94
104
114
124
87
96
105
114
80
88
96
104
73
80
87
94
66
72
78
84
59
64
69
74
52
56
60
64
45
48
51
54
38
40
42
44
*36
*36
*36
PITCH OF SLOPED CEILING
4/12 5/12
6/12 7/12
8/12
6
8
9
10.5
5
7
8
9.5
4
6
7
8.5
3
5
6
7.5
2
2.5
3
3.5
1
1.5
2
2.5
1
1
1
1.5
1
1
1
1
11/12
12/12
134
144
123
132
112
120
101
108
90
96
79
84
68
72
57
60
46
48
*36
36
9/12 10/12 11/12 12/12
12
13.5
15
16.5
18
11
12.5
14
15.5
17
10
11.5
13
14.5
16
9
10.5
12
13.5
15
4
4.5
5
5.5
6
3
3.5
4
4.5
5
2
2.5
3
3.5
4
1
1.5
2
2.5
3
All measurements are in inches.

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Superpro

Table des Matières