6. Menu 3 - Alarm log menu

The alarm log display "3" has 13 sub items "301" – "313".
Display
Name
301
Inlet
302
Outlet
303
Brine in
304
Brine out
305
Outside temp
306
Suction SH
307
High press.
308
Low press.
309
EV position
310
Current
311
EV firmware
312
Application
313
Application

7. Menu 4 - Coded menu

The coded menu is locked and can only be enabled by entering the correct
code. When unlocking this menu a flag is set that can only be reset by
reprogramming the firmware.
Pushing "OK" button in "Cod." display will enter the "enter code menu". The
leftmost digit in the display will start flashing and the digit can be altered by
using the up and down buttons. Pushing the "OK" button again moves on to
the mid digit and the procedure restarts again. When the rightmost digit has
been altered and the code is correct, pushing the "OK" button will unlock the
Coded menu and the "coded menu flag" will be set. The display will now go
to the coded menu. If the code is incorrect the display goes back to the main
menu again and nothing else happens.
Note! Only an authorised service engineer is allowed to log in to the Factory
!
settings coded option. Severe operational problems and faults may occur
affecting the product if values are amended without authorisation. Note that in
such cases the warranty terms do not apply.
Description
Primary circuit inlet temperature when the alarm
was activated
Primary circuit outlet temperature when the alarm
was activated
Ground source inlet temperature when the alarm
was activated
Ground source outlet temperature when the alarm
was activated
Outside coil temperature when the alarm was
activated
Suction gas super heat when the alarm was
activated
High pressure when the alarm was activated
Low pressure when the alarm was activated
Valve position when the alarm was activated
Current (soft starter) when the alarm was activated EA + EP
EVO firmware version
Application SW version, high digits.
Application SW version, low digits.
English
CTC EcoAir /
CTC EcoPart
EA + EP
EA + EP
EP
EP
EA
EA + EP
EA + EP
EA + EP
EA + EP
EA + EP
EA + EP
EA + EP