Menu 2 - Relay Menu - CTC Basic display Instructions D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 70
English
126
EVD Status
127
HP Status
128
Anti-freeze brine C
129
Anti-freeze brine diff
130
Anti-freeze auto reset
131
Fan 0-10 / PWM
132
Drip tray Heater Off
EN
delay
133
Fan Low speed

5. Menu 2 - Relay menu

The relay display 2 has 7 sub items "201" – "207". The relay display will
show the status of the relay as "On" or "Off".
Display
Name
201
Relay Comp.
202
Relay fan speed High
203
Relay Brine pump
204
Relay Charge pump
205
Relay Heating cable
206
Relay Defrost, 4-way valve Defrost, 4-way valve relay status (on/off)is shown
54
54
CTC Basic display
EVD status is shown by displaying the
corresponding decimal value of the status
EVD status
0: ---
1: Close
2: Close
3: Std-by
4: Pos
5: Pos
6: Wait
7-13: On
14: Init
HP status is shown by displaying the
corresponding decimal value of the status.
0 = Compressor_off_start_delay.
1 = Compressor_off_redy_to_start
2 = Compressor_wait_until_flow
3 = Comperssor_on_heating
4 = Defrost_active
5 = Compressor_on_cooling
6 = Compressor_off_blocked
7 = Compressor_off_alarm
8 = Function_test
Antifreeze alarm set point for ground source
circuit
Ground source antifreeze alarm differential
Reset antifreeze alarm, ground source circuit.
Outside exchanger fan signal:
0: Output Y2 used as 0-10V signal
1: Output Y2 used as PWM signal
Off delay for the drip tray heater and the heating
cable after defrost in seconds.
Activates low speed for the fan.
Description
Compressor relay status (on/off) is shown here
Fan speed high relay status (on/off)is shown here
Brine pump relay status status (on/off)is shown here
Charge pump relay status (on/off) is shown here
Heating cable relay status (on/off)is shown here
here
EA + EP
EA + EP
EP
EP
EP
EP + EA
EA
EA
CTC EcoAir /
CTC EcoPart
EA + EP
EA
EP
EA + EP
EA
EA