STEP 2
Watts Chrome Top Mount Faucet Installation
Mounting Hole Size
Torque on Toggle Bolt
Gather and identify the faucet pieces.
Step A – Remove faucet base, faucet spout and
parts bag .
Step B – Connect the
" BLUE tube to the
3
8
of the faucet .
Step C – From above the sink, feed the faucet tubing & toggle bolt
down through the 1¼" mounting hole in the sink . Ensure
that the soft rubber gasket has the protective white paper
removed from both sides and is uniformly positioned in
between the base of the faucet and the top of the sink .
Step D – Align the faucet base so that the handle is on the right side
and the base is sitting flush on the sink top . Using a phillips
head screwdriver, turn the screw located down the hole
where the spout will be installed, clockwise until the toggle
bolt secures the faucet base snug onto the sink top .
Step E – Once the faucet base is securely fastened to the sink top,
insert the faucet spout into the faucet base until it is fully
seated . Turn the handle up (away from you) to the "OFF"
position .
Drain Saddle Installation. See page 5 from IOM-WQ-PWRO4
MINIMUM
MAXIMUM
1"
1
1
"
4
5 lb.in. (max)
" tube from the
3
8
" BLUE Fitting on base
3
8
STEP 3
Adapt-A-Valve™ Installation
Verify contents prior to installation:
( 2 ) - Plastic Adapt-a-Valve™ & Black Collet
( 2 ) - Brass Adapter no washer
( 2 ) - Brass Adapter with black washer
( 2 ) - White rubber washer
NOTICE
Water supply line to the system must be from the cold water
supply line only. Hot water will severely damage your system.
NOTICE
Do not use Teflon tape with the Adapt-A-Valve™.
For
" Configuration
3
8
(With Brass Fittings)
* Insert White Washer
Hot
Supply
Step A – Turn off the cold and hot water supply to the faucet by
turning the angle stop valve completely off .
Step B – Open cold and hot water sink faucet to relieve pressure .
Step C – Choosing the configuration that fits your plumbing, attach
the Adapt-A-Valve™ as illustrated in the photos above .
STEP 4

Reverse Osmosis Module Mounting

Step A – Determine best location for the
RO module to be mounted to
allow for future system main-
tenance . The parts bag has 2
self-tapping screws . Using an
electric drill with a Phillips bit,
screw them into the cabinet
wall 6" apart and 16" from the
bottom of the cabinet .
Do not cut any RO system tubes at this time
5
For
" Configuration
1
2
(Without Brass Fittings)
" Configuration
1
2
Cold
Supply