NON-SERIOUS ALARMS
Thermostat OFF
■ Code A03 = water sensor error
■ Code A04 = remote humidity probe error (only if a remote
temperature probe is installed)
■ Code A05 = internal humidity probe error
N.B.: the alarm code is displayed only when the thermostat
is switched off
MODBUS
The protocol implemented in the controller is Modbus RTU
(9600, N, 8, 2) on RS485
FUNCTIONS IMPLEMENTED
■ 0x03 : Read Holding Registers
■ 0x04 : Read Input Registers
■ 0x10 : Write Multiple registers
EXCEPTIONS IMPLEMENTED
Exception Code 02: Invalidate data address
LIST OF SUPERVISION PARAMETERS
ADDRESS
REGISTER
Status
0
Speeds
1
Air temperature
2
3
Humidity
Water temperature
4
P00: Confi guration
5
6
P05: Confi g. DIN
T. Active setpoint
7
T. User setpoint
8
LCD version
9
Digital 1
50
-
51
Setpoint - Cooling
52
Setpoint - Heating
53
Minimum Setpoint – Cool.
54
Maximum Setpoint – Cool.
55
Minimum Setpoint – Heat.
56
Maximum Setpoint – Heat.
57
Speeds
58
59
Economy Correction
FWEC2
Advanced electronic controller
FC66002764
DESCRIPTION OF READ-ONLY REGISTERS [R]
■ "Staus" "REGISTER"
Bit 15
-
Bit 7
Thermostat ON
Vh
-
On/Off: unit status (0: Off, 1=On)
-
S/W: operation mode (0: S=cooling,1:W=heating)
-
P01: "on unit/wall-mounted" parameter
-
Eco: Economy logic active
-
Min.T: Minimum Temperature logic selected
-
Alarm: general alarm indication (activated when any of
the managed alarms is triggered)
-
Vc: status of digital output Vc
-
Vh: status of digital output Vh
-
DI1: logical value of dig. input 1 (the physical status of the
input depends on the associated logic)
-
DI2: logical value of dig. input 2 (the physical status of the
input depends on the associated logic)
-
P07: "DIN 2 Logic" parameter
-
P06: "DIN 1 Logic" parameter
-
Dehum: dehumidifi cation ON (0:no, 1:yes)
-
P04: "water probe present" parameter
■ "SPEED" REGISTER: current operating speed of the
indoor unit
-
0: fan OFF
-
1: extra-low speed
TYPE
U.M.
-
2: low speed
R
-
-
3: medium speed
-
4: high speed
R
-
■ "AIR TEMPERATURE" REGISTER: room temperature
R
[°C/10]
read by the controller and shown on the display (N.B.:
this temperature corresponds to the reading of the remote
R
%
probe if the controller is located on the unit, or the read-
R
[°C/10]
ing of the internal probe in the case of a wall-mounted
controller and remote probe disconnected)
R
-
■ "HUMIDITY" REGISTER: room humidity read by the
R
-
controller via the probe associated with the temperature
probe used
R
[°C/10]
■ "WATER TEMPERATURE" REGISTER: value read by the
R
[°C/10]
water probe (SW)
■ "P00" Register: "Controller confi guration" parameter
R
-
■ "T. ACTIVE SETPOINT" Register: setpoint used for tem-
perature control
■ "T. USER SETPOINT" Register: setpoint programmed by
R/W
-
the user (it may differ from the active setpoint due to cor-
R/W
-
rections based on economy logics,...or use of the setpoint
imposed by the supervision software)
R/W
[°C/10]
■ "LCD VERSION" Register : defi nes the controller type and
software version installed (0xHHSS: HH: ASCII character,
R/W
[°C/10]
SS:sw version)
R/W
[°C/10]
R/W
[°C/10]
R/W
[°C/10]
R/W
[°C/10]
R/W
-
R/W
[°C/10]
H
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
-
P04
Deum
P06
P07
L
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Vc
Alarm
MinT
Eco
P01
Installation and operation manual
Bit 9
Bit 8
DI2
DI1
Bit 1
Bit 0
S/W
On/Off
9

Publicité

Table des Matières
loading

Table des Matières